sec.4b
−−−−
3
2 VOICE - Technical Manual
DOOR PHONE APARTMENT STATIONS
2VOICE COMFORT DOOR PHONE Ref. 1183/5
INSTALLATION - TECHNICAL CHARACTERISTICS - DIP-SWITCH CONFIGURATION
INSTALLATION
To install door phone perform the following operations:
Remove the door phone cover
Fix the base to the wall with the provided screws and screw
anchors
Con
fi
gure the programming dip-switches
Connect the wires from the system to the terminal board
Mount again the cover
155
cm
(*)
(*) For disabled or special needs users of the D1 type (elderly), D2
type (lower limb motor dif
fi
culties) or D3 type (upper limb motor
dif
fi
culties), the centre of the device must be arranged at a height
comprised between 110 cm and 130 cm with respect to the
fl
oor. For
more details, see technical standard CEI 64-21:2016-12 – Residential
environments. Systems suited for use by people with disabilities or
special needs..
TECHNICAL CHARACTERISTICS
Power supply voltage: .......................................................
36 – 48 Vdc
Max. current consumption : in operation .......................
70 mA max
in standby ..........................
3 mA max
Operating temperature : ..............................................
-5 °C ÷ +45 °C
Max. humidity: ........................................................................
90% UR
Dimensions (WxHxD): .............................................
90 x 200 x 52 mm
CLEANING
You can clean the door phone by rubbing it gently with a damp
cloth.
DIP-SWITCH CONFIGURATION
ON
=
OFF
=
ON
ON
INT
ON
2
1
CODE
ON
4
3
2
1
5
8
7
6
Default setting
: default door phone settings are:
USER = 126
INDOOR STATION = 0
The dip switches must always be arranged in the correct setting
for correct operation of the system in this case.
CODE
: user code
Use the CODE dip switches from 2 to 8 (2= most signi
fi
cant
bit - 8= least signi
fi
cant bit) to set the required code. Dip
switch 1 must be OFF.
•
•
•
•
•
2VOICE COMFORT DOOR PHONE
Ref. 1183/5
Set a number from 0 to 126 according to the following rules:
No two apartments in the system can have the same user code.
Indoor stations in parallel in the same apartment must have the
same user code
User codes be consecutive in the same column must.
•
•
•
CODE 3
CODE 2
CODE 1
CODE 0
CODE 7
CODE 6
CODE 5
CODE 4
CODE 11
CODE 10
CODE 9
CODE 8
CODE 15
CODE 14
CODE 13
CODE 12
CODE 19
CODE 18
CODE 17
CODE 16
CODE 23
CODE 22
CODE 21
CODE 20
CODE 27
CODE 26
CODE 25
CODE 24
CODE 31
CODE 30
CODE 29
CODE 28
CODE 35
CODE 34
CODE 33
CODE 32
CODE 39
CODE 38
CODE 37
CODE 36
CODE 43
CODE 42
CODE 41
CODE 40
CODE 47
CODE 46
CODE 45
CODE 44
CODE 51
CODE 50
CODE 49
CODE 48
CODE 55
CODE 54
CODE 53
CODE 52
CODE 59
CODE 58
CODE 57
CODE 56
CODE 63
CODE 62
CODE 61
CODE 60
CODE 67
CODE 66
CODE 65
CODE 64