background image

sec.3h 

−−−−

 

1

2 VOICE - Technical Manual

SECTION 3H

CALL MODULE

Download from www.urmet.com Technical Manuals area.

SECTION CONTENTS

DIGITAL CALL MODULE

Ref.1083/19 (2 Modules) 

2

PERFORMANCES ............................................................................2

DESCRIPTION OF TERMINALS .......................................................2

TECHNICAL CHARACTERISTICS ....................................................3

DEFAULT CONFIGURATION ...........................................................3

INSTALLATION .................................................................................3

  Camera module connection .........................................................4

 Product 

list 

...................................................................................4

PROGRAMMING ..............................................................................4

 Con

fi

 guration programming .........................................................4

 Con

fi

 guration parameter ...............................................................4

 Name 

programming 

......................................................................6

  Programming of door opener code ..............................................6

 Audio 

adjusting 

.............................................................................6

  Call to users ..................................................................................7

  Call by entering physical code .....................................................7

  Call by entering logical code ........................................................7

  Call by selecting name from repertory .........................................7

  Call to switchboard .......................................................................7

  Communication and door opening ...............................................7

  Transmission of special codes .....................................................8

 Lock 

management 

........................................................................8

  Entry of door opener codes ..........................................................8

 “Postman” 

function 

......................................................................8 

Programming via Bluetooth ..........................................................8

CAMERA MODULE Ref. 1748/40 

9

TERMINAL PINS DESCRIPTION ......................................................9

INSTALLATION .................................................................................9

VIEWING ANGLES .........................................................................11

REPERTORY MODULE Ref. 1148/50 

11

BLANK MODULE Ref. 1148/59 

11

Summary of Contents for 1083/19

Page 1: ...ming 4 Configuration parameter 4 Name programming 6 Programming of door opener code 6 Audio adjusting 6 Call to users 7 Call by entering physical code 7 Call by entering logical code 7 Call by selecti...

Page 2: ...t feature Postman function direct opening of main entrance with key on days and at times programmed Direct call to switchboard if two buttons are pressed at the same time Management of main entrance H...

Page 3: ...ecret Vehicle entrance door opener time 1s Type of vehicle entrance door opener secret Password 1000 Number of surveillance cameras 0 Key click Yes Postman function no To restore the default values po...

Page 4: ...Use the arrow keys to scroll the programming menu Press to access the selected second level menu press X to quit programming In the language menu select the operating language and confirm with CONFIG...

Page 5: ...tricted The door unit behaves as follows in the two cases Secret Private pressing the door opener button of an apartment station the electric lock of the call station is released only if a call has be...

Page 6: ...de is not to be assigned to the user inserted press If a door opener code to be assigned to the user inserted enter the door opener code which must be a 4 digit number from 0001 to 4999 This code will...

Page 7: ...e system is free the call is made and for the entire pick up wait time max 60s the display shows CALLING If the system is busy the display shows LINE BUSY WAIT When the system is free again the call c...

Page 8: ...the call module the door pedestrian or vehicle can be opened entering this code The main entrance lock is activated for codes from 0001 to 4999 the vehicle entrance lock is activated for codes from 5...

Page 9: ...systems TERMINAL PINS DESCRIPTION V3 Video signal for system with coaxial cable modules V5 Video signal ground for system with coaxial cable R1 Camera power supply negative TC Camera power supply pos...

Page 10: ...LLATION CAMERA MODULE Ref 1748 40 6 If required replace the cross slotted screws with security screws provided with the camera 5 Adjust the camera orientation A B A B Position the frame on the module...

Page 11: ...g field REPERTORY MODULE Ref 1148 50 Repertory modules are normally used to indicate the house number or contain other information Power terminals 0 and 12 to light the unit via LEDs The procedure for...

Page 12: ...12 sec 3h 2 VOICE Technical Manual CALL MODULE...

Reviews: