Function Motion(Timer Mode) 

In  mode   =  A timer mode of operating by setting cycle and step (see Table #2)  

                (Must disconnect the temp sensor for using timer mode)  

                If sensor is snapped while the sensor mode has been used, the senor mode is converted to the timer mode automatically.  

  

 TIMER Function  

* Must disconnect the temp sensor for using timer functions.  

  Push 

 and 

 keys simultaneously for 3 sec,  ‘tn'  displays. Push 

 key once again, the ‘EN’ displays.  ‘EN’ as the mode by sensor is same to the present mode. Push 

 

key once again, then ‘In’ displays. At this time push 

 and 

 keys simultaneously, then  the present cycle value displays. For setting cycle, use 

 or 

 key. After setting the 

cycle value, push 

 and 

 keys simultaneously, then  ‘AU’ flickers, the cycle value is saved, and the present intensity displays.  

 

How to set (serviceman)  = push 

 and 

 keys simultaneously–  ‘tn’ displays on the screen- select ‘tin’ - push 

 and 

 keys simultaneously–Cycle value d splays(Cycle) – 

select Cycle (basic 3 min)  

                         - Set cycle value  - push 

 and 

 keys simultaneously  - ‘AU’ flickers – saved   

* It is recommended for the end-user not to set.  

How to use by the end-user =  select the intensity to be used with 

 and/or 

 key (basic single-step) 

Step 

Output (0N) 

Output (OFF) 

Remarks 

15 sec * 

45 sec * 

S

 

 

 

S: 

Selected cycle value     

 

     In case of 1 min, 

S

=1    

     In case of 3 min, 

S

=3      

     In case of 5 min, 

S

=5        

           *

 

 

           *

  

 

 (in case of 20 min, 

S

 = 20, value multiplying by 20)

 

 

 

 (in case of 60 min, 

S

 = 60 , value multiplying by 60)    

This will be the length of ON and OFF

  

20 sec * 

S

 

40 sec * 

S

 

25 sec * 

S

 

35 sec * 

S

 

30 sec * 

S

 

30 sec * 

S

 

35 sec * 

S

 

25 sec * 

S

 

40 sec * 

S

 

20 sec * 

S

 

45 sec * 

S

 

15 sec * 

S

 

50 sec * 

S

 

10 sec * 

S

 

50 sec * 

S

 

10 sec * 

S

 

10 

50 sec * 

S

 

10 sec * 

S

 

Table # 2 

Summary of Contents for UTH-170R

Page 1: ...Manual for Use and Installation UTH 170R ...

Page 2: ...Connection and Fixing Fixing Connection Method 1 ...

Page 3: ...Connection and Fixing Fixing Connection Method 2 ...

Page 4: ...ols the controller power ON OFF and sets temp set UP DOWN Use the remote control toward the front The function of fine setting motion or the sequence motion is intentionally removed for reducing the occurrence of malfunction For fine setting please use the keys on the controller How to Set Set if necessary to change the range of set temp finely tn displays on the Temp display Screen after pushing ...

Page 5: ...verheating sensor sensing temp exceeds the set temp OPTION Correction Temp Set ES 00 9 10 Scope for correcting the actual temp deviation Table 1 Sensor Mode TIMER Functions Must disconnect the temp sensor for using timer functions see Table 2 Push and keys simultaneously for 3 sec tn displays Push key once again the EN displays EN as the mode by sensor is same to the present mode Push key once aga...

Page 6: ...ickers the cycle value is saved and the present intensity displays How to set serviceman push and keys simultaneously tn displays on the screen select tin push and keys simultaneously Cycle value d splays Cycle select Cycle basic 3 min Set cycle value push and keys simultaneously AU flickers saved It is recommended for the end user not to set How to use by the end user select the intensity to be u...

Page 7: ...perature Coefficient Epoxy Molding Degree of Precision 1 25 s rating resistance 5000 ohm Beta Constant 4000 0 K Quantity SENSOR 1 for sensing Temp SENSOR 2 for checking Overheating Option Function Capacity Safety Device Snapping Short circuit of Sensor Wires If Temp Sensing Sensor is snapped converted to Timer mode automatically and work If short Circuit ES displays and output is OFF Overheating P...

Reviews: