Page 11 of 22
INITIAL FIRING
When lit for the first time, the appliance may emit an odor resulting from evaporation of paint and
lubricants used in the manufacturing process. This is normal and will subside after the unit has run
for an hour or so.
MANIFOLD PRESSURE REGULATOR ADJUSTMENT
The manifold pressure regulator controls gas input and flame height, and is pre-adjusted at the
factory. No further adjustment is required.
PRIMARY AIR ADJUSTMENT
Aeration is factory set but may need adjustment for altitude or movement during shipping. The
adjustment for the air shutter is found on the mixing tube which is located underneath your appliance.
Loosen the screw which holds the aeration adjustment shutter in place and rotate the adjustment
shutter to increase or decrease primary air (see below) and tighten the screw. Increasing the primary
air will cause the flame to appear more transparent and blue. Decreasing the primary air will cause
the flames to appear more yellow or orange. Evaluate the aeration only after the unit has warmed up
approximately 15 minutes. If the unit shows signs of carbon build up increasing the primary air
should alleviate this problem.
Caution: Parts requiring adjustment during operation may be hot.
Aeration adjustment is important for the correct functioning of the appliance. Carbon build up, flame
lifting or any malfunction due to improper aeration adjustment during installation is not covered under
the factory warranty.