8.0 Laying the Gas Supply:
8.1 Gas supply pipe should be sized as per the requirements of BS 6896. The pipe sizing must be sufficient
to deliver the volume of gas to the outdoor gas burner with all other gas appliances in the home operating
from the same meter, running at the same time.
8.2 It is highly recommended to install an easily accessible isolating shut off valve along the gas line to the
Urban Fire appliance, which should be easily accessible to the user.
8.3 The gas supply should be properly located away from pathways or areas where the hose may be subject
to accidental damage. If in doubt use Tracpipe.
9.0 Connecting the Gas Supply to the UF950RC
S
outdoor gas burner:
9.1 A flexible stainless steel gas supply tube is fitted with 8mm compression fitting termination, supplied with
this fire. Connect the incoming gas supply directly to the 8mm fitting. Check gas tightness.
9.2 An accessible inline isolation or service valve should also be fitted.
10.0 Fixing the fire into a masonry enclosure, firetable or fireplit:
The burner must fit - and sit securely - into a burner tray or rebated masonry (see Section 3.0 Cutout) and
does not need to be permanently fixed, since it should be easily removable for servicing.