Urban Fires UF950RCS Installation & Use Instructions V3.10 Nov 2019 Page
6
2.0 Power Supply for ignition:
This appliance should only be operated by the 6v transformer supplied, from a 240v supply.
In an emergency, such as a power or transformer failure, 4 x AA size batteries can be used for ignition.
These can be located into the Receiver Unit inside the control box under the IP-rated cover but MUST
NOT be used at the same time as transformer power.
2.1 Installing Batteries:
To install batteries, the complete burner assembly must be lifted out from its housing (i.e firebox, firetable,
etc). The gas supply is connected via a flexible supply hose. Remove the control lid cover to gain access to
the Receiver Unit pictured above. To remove the cover of the Receiver Unit itself pull the cover back. Ensure
the batteries are placed in the correct orientation. Disconnect the transformer.
Once batteries have been placed inside, replace the cover and seal the IP-rated Control Box assembly
2.2 Normal Power Source: (Supplied transformer)
To connect the UF950RC
S
to 240v mains electricity
instead of using batteries for ignition, you should do so
using the transformer supplied.
Route the transformer cable through the side of the
housing via one of the bungs supplied to protect
against moisture damage. The bung will need to be
punctured to enable this. Remove the batteries and
connect the transformer to the fire by plugging the
connector of the transformer into the Receiver Unit.
Use some silicon to seal the bung where the cable
passes through the bung.
The transformer will require a 240v supply and a standard 3-pin socket and MUST BE contained
within a suitable IP-rated waterproof enclosure. (Not supplied).
Here are details of a suitable enclosure:
http://www.tlc-direct.co.uk/Products/GWBX645.html
You will need the following components:
- GWBX645 150 x 110 x 140mm IP56 Moulded Box
- EK241B 13mm Nylon Compression Gland Black for Cable 5-7mm
- EK79B 13mm Nylon Lock Ring - Black