Urban Fires UF950RC Installation & Use Instructions V3.8 April 2018 Page 12
11.0 Connecting the optional Touch Control Panel:
This option is no longer available and is replaced completely by the operation of the Remote Control hand-
set as standard.
12.0 Testing of the power switch and spark ignition:
IMPORTANT: Before the operating pressure can be checked, the power switch and spark ignition must be
tested.
12.1 This can be done with the gas supply either turned on or off.
12.2 Run through the steps for igniting the pilot (refer to section 14.0 for operating instructions).
13.0 Placement of the Crystalight moulded ceramic glass gas fire media:
13.1 Two (or four) 30mm x 30mm stainless steel plates are supplied to cover the finger holes before placing
the Crystalight gas media over the burner tray. These plates are supplied within the bubblewrap packaging
or in a separate polythene bag.
TIP: Use the finger holes to easily remove the burner assembly from the masonry cutout or burner tray.
13.2 Urban Fires Crystalight gas media should be evenly spread in ONE LAYER. Do not heap or mound the
fuel bed media. Attempt to get an even spread across the top of the burner. Do not allow media to enter the
pilot guard or pilot assembly.
13.3 Ensure the pilot flame is left clear and unimpinged by the Crystalight gas media.