background image

Part No. 550-142-026/0508

 

Model CF1400-W 

Figure 1

 

Model CF2300A-W

Figure 2

Dimensions in Inches

Burner 

Model 

Number

Length 

(From Mounting Flange To 

Label Area On Burner Front)

Overall 

Width

Motor Size 

H.P.

Standard Motor 

Electrical 

Characteristics

Optional Motor 

Electrical 

Characteristics

CF1400-W

20.75

22.50

1/2

120/60/1

208-240/60/1*

208-240-480/60/3

CF2300A-W

21.25

24.00

3/4

120/60/1

208-240/60/1*

208-240-480/60/3

CF2500-W

23.50

27.00

2

240/60/1

208-240-480/60/3

CF3500A-W

23.50

27.00

2

240/60/1

208-240-480/60/3

* Optional motor contactor supplied.

Beckett

 

Oil Burners

Models CF1400-W, CF2300A-W, 

CF2500-W, CF3500A-W

Burner Specification 

& Data Sheet

Water & Steam Boilers – Series 2

88

For Gas, Light Oil, & Gas/Light Oil – Fired Burners

Summary of Contents for Beckett CF1400-W

Page 1: ...lectrical Characteristics CF1400 W 20 75 22 50 1 2 120 60 1 208 240 60 1 208 240 480 60 3 CF2300A W 21 25 24 00 3 4 120 60 1 208 240 60 1 208 240 480 60 3 CF2500 W 23 50 27 00 2 240 60 1 208 240 480 60 3 CF3500A W 23 50 27 00 2 240 60 1 208 240 480 60 3 Optional motor contactor supplied Beckett Oil Burners Models CF1400 W CF2300A W CF2500 W CF3500A W Burner Specification Data Sheet Water Steam Boi...

Page 2: ...65 CF2500A W WL7301 1088 21 50 11 26 0 65 CF2500 W WL7301 1188 23 50 12 30 0 65 CF2500 W WL7302 1288 26 00 13 00 0 65 CF3500A W WL7401 1388 28 50 15 00 0 70 CF3500A W WL7402 Boiler Model Number Standard Combustion Control Air Tube Combination Starting Head Setting Approximate Air Settings Low Fire High Fire 488R Beckett 7505P1515 CC CF66KD 4 39 54 488 Beckett 7505P1515 CC CF66KD 4 39 54 588 Becket...

Page 3: ...d by Underwriters Laboratories Inc Underwrit 8 ers Laboratory Canada State of Connecticut Fire Marshal state of Massachusetts city of New York MEA and others Settings shown are for initial set up Final settings should be 9 determined after combustion readings Boiler Model Number Oil Nozzle s Operating Oil Pressures PSIG Fuel Unit Burner Motor Driven 3450 RPM Preferred nozzles Alternate nozzles Qty...

Page 4: ...rnal To Appliance Overall Height Bolt Circle Centerline To Pump Centerline To Motor Square Flange Width Height CF1400 W CF66KD 24 75 4 00 5 50 20 63 13 50 10 25 9 50 9 82 12 00 CF2300A W CF66KG 25 25 4 00 6 50 21 13 15 60 10 25 10 40 12 00 12 00 CF2300A W CF66KS 25 25 4 00 8 13 21 13 15 60 10 25 10 40 12 00 12 00 CF2500 W CF66KP 26 25 4 00 6 50 22 13 17 70 10 25 12 70 14 10 12 00 CF3500A W CF80KM ...