background image

C

L

L

C

12 1/2"

6 1/4"

6 1/4"

4"

MINIMUM

1/2"
MINIMUM CLEAR *

22" CLEARENCE FOR

COVER REMOVAL

3" RECOMMENDED FOR

OIL SUPPLY LINE CLEARENCE

15"

7 1/2"

SK9892

Remove the four Phillip’s head screws from the 
existing square plate on the front of the burner. 
Discard the old square front plate.
Attach the new front plate using the four Phillip’s 
head screw removed in Step 3. 
Reattach the air tube assembly using the four air 
tube mounting screws. Reinstall the nozzle line 
electrode assembly, secure with the spline nut 
and reattach the copper oil line. Before placing 
the burner in service check for leaks, and make 
sure the Z dimension is correct per the set-up 
instructions in the Beckett Installation Manual 
supplied with your burner. 
To install the cover, place the guide pins through 
the triangular holes in the cover mounting plate 
and snap the latches over the edge of the 
mounting plate.
To latch the bottom of the cover, slightly pull on 

3.

4.

5.

6.

7.

INSTALLATION 

INSTALLATION 
INFORMATION

INFORMATION

AF/AFG/CF375/NX BURNER COVER 

AF/AFG/CF375/NX BURNER COVER 

(WITH ONE PIECE MOUNTING PLATE) 

(WITH ONE PIECE MOUNTING PLATE) 

PART NO. 5207302U & 5207303U

PART NO. 5207302U & 5207303U

Figure 1 

Review the existing oil lines. They must be installed so 

that they will pass out through the slot in the bottom of 
the cover. If they do not, they must be removed and rein-
stalled later. (See Figure 3.)

.

Preparing to Install the Cover

Remove the burner from the appliance. Loosen 
the two front igniter hold down screws and swing 
the igniter back on its hinge. Remove the copper 
oil line from the escutcheon plate by loosening 
the spline nut and removing the line. Pull the 
nozzle line electrode assembly out of the burner 
housing and set to one side.
Remove the four air tube mounting screws and 
detach the air tube assembly. Retain the screws 
and air tube assembly for reinstallation. (Refer to 
Figure 2.)

1.

2.

Please read and understand the manual supplied with this 

equipment. This equipment must be installed, adjusted and put 
into operation only by a qualifi ed individual or service agency 
that is:

Licensed or certifi ed to install and provide technical ser-

vice to oil heating systems.

Experienced with all applicable codes, standards and 

ordinances.

Responsible for the correct installation and commission of 

this equipment.

Skilled in the adjustment of oil burners using combustion 

test instruments.

The installation must strictly comply with all applicable codes, 

authorities having jurisdiction and the latest revision of the Na-
tional Fire Protection Association Standard for the installation 
of Oil-burning Equipment, NFPA 31 (or CSA B139 and B140 in 
Canada).

Regulation by these authorities take precedence over the gen-

eral instructions provided in this installation manual.

1.

2.

3.

4.

Incorrect installation, adjustment, and 

use of this burner could result in severe 
personal injury, death, or substantial 
property damage from fi re, carbon mon-
oxide poisoning, soot or explosion.

Professional Service     

Required

WARNING

!

Disconnect electrical power before installing or servicing the 

burner.

Electrical shock can cause severe personal 

injury or death.

Electrical Shock Hazard

WARNING

!

Notice Special Requirements

 
Figure 1 shows the required clearances around the 

burner for a successful and easy cover installation.

System Installation Requirements

Reviews: