U200 control panel to control 1 access way
Type of accessory
Single
accessory
power (W)
Max no. of
connectable
accessories and
bollards
Total power (W), if
with monostable
solenoid valve
Total power (W), if with
bistable solenoid valve
Monostable solenoid valve
8
6
48
Bistable solenoid valve *
3
8
24
Duty cycle
3
6
18
8
24
Flashing light
25
1
25
25
Traffic light
11
2
22
22
Magnetic loop
2.5
3
7.5
7.5
Total (W)
120.5
102.5
U200 control panel + U201 board to control 2 separated access ways
Type of accessory
Single
accessory
power (W)
Max no. of
connectable
accessories and
bollards
Total power (W), if
with monostable
solenoid valve
Total power (W), if with
bistable solenoid valve
Monostable solenoid valve
8
6
48
Bistable solenoid valve *
3
8
24
Duty cycle
3
6
18
8
24
Flashing light**
25
2
50
50
Traffic light **
11
4
44
44
Magnetic loop
2.5
6
15
15
Total (W)
131
125
113
117
U200 control panel + two U201 boards to control 3 separated access ways
Type of accessory
Single
accessory
power (W)
Max no. of
connectable
accessories and
bollards
Total power (W), if
with monostable
solenoid valve
Total power (W), if with
bistable solenoid valve
Monostable solenoid valve
8
6
48
Bistable solenoid valve *
3
8
24
Duty cycle
3
6
18
8
24
Flashing light ***
25
3
75
75
Traffic light ***
11
6
66
66
Magnetic loop
2.5
9
22.5
22.5
22.5
22.5
Total
(W)
163.5
154.5
145.5
136.5
* The bistable solenoid valves are used in such systems, where the bollard should remain in the higher
position even when voltage is cut off
** If you use the flashing light you cannot use the traffic light
*** According to this configuration, the flashing lights or the traffic lights should be externally supplied.
5.1 Summary table of 24 V accessories’ power demand, expressed in W