background image

3. Test Condition

3.1 Standard Test Conditions

3.1.1 Unless otherwise specified, all performance tests is required conducted at temperature 25°C±2°C,                   
         Humidity less than 45% ~ 75% RH.
3.1.2 Unless otherwise specified, the tested product is required unused within two month after outgoing.

3.2 Standard Charge Mode

"Standard Charge" means at 25±2°C charge to limit voltage with 0.33C constant current, then charge with 
constant voltage until current less than 0.02ItA. 

3.3 Quick Charge Mode

"Quick Charge" means at 25±2°C charge to limit voltage with 0.5 C constant current, then charge with constant 
voltage until current less than 0.02ItA. 

3.4 Standard Discharge Mode

"Standard Discharge" means at 25±2°C discharge to the cut-off voltage with 0.33C current.

3.5 Quick Discharge Mode

"Quick Discharge" means discharge to the cut-off voltage with 0.5C current.

NO.

Items

Criteria

Length: 721±3mm

Width:   403±3mm

Height:  431.5±3mm

Dimension

Self-discharge rate

Operating Temperature 

Approx: 200±15Kg

Charging

0~45°C

Residual capacity

≤3%/month; ≤15%/years

15

16

17

Weight

Discharging

-20~60°C

Recommended operating temperature

15°C~35°C

Reversible capacity

≤1.5%/month; ≤8%/years

Storage Temperature & Humidity Range

Less than 1 month

-20°C~35°C

45% RH~75

% 

RH 

18

Less than 3 months

-10°C~35°C

45% RH~75

% 

RH 

Recommended storage environment

:

15°C~35°C

45% RH~75

% 

RH

14

Long time storage: 
If the battery need be stored for a long time, the voltage should be 52.8V (50% SOC), and stored in the condi-
tion as storage proposal. It need at least one charge & discharge cycle every six months

UE-48Li300

02

www.upowerbatteries.com

66A Tzar Asen Srt.
Sofia, Republic of Bulgary
Tel. (+34) 918 021 649
Fax. (+34) 917 750 542
[email protected]

Summary of Contents for Ecoline UE-48Li300

Page 1: ...Standard charge current Internal resistance Floating charge voltage 51 2V 51 2V 100A 2 3 4 5 7 8 Nominal Voltage Outgoing Voltage 30m 55 2 0 2V Maximum charge current 150A 9 Standard discharge curren...

Page 2: ...ent 3 5 Quick Discharge Mode Quick Discharge means discharge to the cut off voltage with 0 5C current NO Items Criteria Length 721 3mm Width 403 3mm Height 431 5 3mm Dimension Self discharge rate Oper...

Page 3: ...he battery with the current of 0 33C to the cut off voltage and record charge capacity Store the battery at various temperatures for 2h and discharge the battery with 0 33C to the cut off voltage 0 C...

Page 4: ...85 5 C Charge over temperature protection relay Discharge over temperature protection relay Screen Short press a switch light and display screen voltage temperature residual capacity current light up...

Page 5: ...to 12V Pin2 to B Pin2 to A and Pin4 to GND 2 The LCD panel socket Pin1 to 12V Pin2 to B Pin2 to A and Pin4 to GND 3 Battery iron box matching LCD communication shielding wire is about 4m www upowerbat...

Page 6: ...ositive and negative of battery with metal Avoid excessive physical shock or vibration don t hit fall stamp on the battery Without the permission of the manufacturer and guidance forbidden to remove o...

Page 7: ...n not in use for a long time because of its own self discharge charac teristics can also cause discharge to prevent the occurrence of a discharge battery should maintain a certain capacity maintain th...

Reviews: