background image

4. Product Performance

5. Protective Circuit Specification

The batteries are supplied with a LiFePO4 Battery Management System (BMS) that can monitor and optimized 
each single prismatic cell during charge & discharge, to protect the battery pack overcharge, over discharge, 
short circuit. Overall, the BMS helps to ensure safe and accurate running.

NO.

Items

Minimum Capacity

2

3

-20°C

Testing Method

Rated Capacity 

1

300Ah

Criteria

Rest for 1 hour after fully charged, then discharge 
with 0.33C current until the battery reaches the 
discharge cutoff voltage. Repeat above process for 
three times, if the discharge time is not less than 120 
minutes, you can stop and define the Discharging 
current*time value (Ah) as battery capacity.  

295Ah

Discharge 
Temperature 
Characteristics

At 25±5°C discharge the battery with the current of 
0.33C to the cut-off voltage and record charge 
capacity. Store the battery at various temperatures 
for 2h and discharge the battery with 0.33C to the 
cut-off voltage.

0°C

25°C

55°C

≥70%

≥80%

≥100%

≥95%

Charge the battery to full capacity and store it for 28 
days, and then discharge it with 0.33C to the cut-off 
voltage.

Charge Retention 
ability

Residual 
capacity ≥80%

Internal resistance

≤30mΩ

50% battery SOC state frequency of 1 KHZ ac 
resistance tester.

Discharge with the current of 0.33C until it can’t 
discharge, and then rest it for 1h. Charge the battery 
following CC (0.33C)/CV (14.6V) mode to full capacity, 
and then rest it for 1h. Repeat above process until full 
charged capacity is no more than 80% of normal 
value. Accumulated times is defined as cycle life.

4

Cycle life (DOD%100)

≥1875 cycles

5

6

Recovery 
capacity ≥90%

03

UE-48Li300

www.upowerbatteries.com

66A Tzar Asen Srt.
Sofia, Republic of Bulgary
Tel. (+34) 918 021 649
Fax. (+34) 917 750 542
[email protected]

Summary of Contents for Ecoline UE-48Li300

Page 1: ...Standard charge current Internal resistance Floating charge voltage 51 2V 51 2V 100A 2 3 4 5 7 8 Nominal Voltage Outgoing Voltage 30m 55 2 0 2V Maximum charge current 150A 9 Standard discharge curren...

Page 2: ...ent 3 5 Quick Discharge Mode Quick Discharge means discharge to the cut off voltage with 0 5C current NO Items Criteria Length 721 3mm Width 403 3mm Height 431 5 3mm Dimension Self discharge rate Oper...

Page 3: ...he battery with the current of 0 33C to the cut off voltage and record charge capacity Store the battery at various temperatures for 2h and discharge the battery with 0 33C to the cut off voltage 0 C...

Page 4: ...85 5 C Charge over temperature protection relay Discharge over temperature protection relay Screen Short press a switch light and display screen voltage temperature residual capacity current light up...

Page 5: ...to 12V Pin2 to B Pin2 to A and Pin4 to GND 2 The LCD panel socket Pin1 to 12V Pin2 to B Pin2 to A and Pin4 to GND 3 Battery iron box matching LCD communication shielding wire is about 4m www upowerbat...

Page 6: ...ositive and negative of battery with metal Avoid excessive physical shock or vibration don t hit fall stamp on the battery Without the permission of the manufacturer and guidance forbidden to remove o...

Page 7: ...n not in use for a long time because of its own self discharge charac teristics can also cause discharge to prevent the occurrence of a discharge battery should maintain a certain capacity maintain th...

Reviews: