background image

03

NO.

Items

-20°C

Testing method

Internal resistance 

3

≤25mΩ

50% battery SOC state frequency of 1 KHZ ac 

resistance tester. 

Criterion

Discharge 
Temperature 
Characteristics

At 25±5°C discharge the battery with the current of 
0.33C to the cut-off voltage and record charge 
capacity. Store the battery at various temperatures 
for 2h and discharge the battery with 0.33C to the  
cut-off voltage.

0°C

25°C

55°C

≥70%

≥80%

≥100%

≥95%

Charge the battery to full capacity and store it for 28 
days, and then discharge it with 0.33C to the cut-off 
voltage.

Charge Retention 
ability

Residual

capacity ≥80%

Discharge with the current of 0.33C until it can’t 
discharge, and then rest it for 1h. Charge the battery 
following CC (1C)/CV (43.8V) mode to full capacity, 
and then rest it for 1h. Repeat above process until full 

charged capacity is no more than 80% of normal 

value. Accumulated times is defined as cycle life.

4

Cycle life (DOD%100)

≥2500 cycles

5

4. Product Performance

6

Recovery

capacity ≥90%

Rest for 1 hour after fully charged, then discharge with 
0.33C current until the battery reaches the discharge 
cutoff voltage. Repeat above process for three times, 
if the discharge time is not less than 180 minutes, you 
can stop and define the Discharging current*time 
value (Ah) as battery capacity.    

Rated Capacity 

1

100Ah

Minimum Capacity 

2

98Ah

UE-36Li100

www.upowerbatteries.com

66A Tzar Asen Srt.
Sofia, Republic of Bulgary
Tel. (+34) 918 021 649
Fax. (+34) 917 750 542
[email protected]

Summary of Contents for Ecoline UE-36Li100

Page 1: ...f the battery pack NO Items Criteria 100Ah 98Ah 3 84KWh Rated Capacity Minimum Capacity Energy Floating charge voltage Internal resistance Limited charge voltage 38 4V 38 4V 41 4 0 2V 2 3 4 5 6 7 Nomi...

Page 2: ...3 1 1 Unless otherwise specified all performance tests is required conducted at temperature 25 C 2 C Humidity less than 45 75 RH 3 1 2 Unless otherwise specified the tested product is required unused...

Page 3: ...an t discharge and then rest it for 1h Charge the battery following CC 1C CV 43 8V mode to full capacity and then rest it for 1h Repeat above process until full charged capacity is no more than 80 of...

Page 4: ...ischarge release method Charging recovery UE 36Li100 5 Protective Circuit Specification The batteries are supplied with a LiFePO4 Battery Management System BMS that can monitor and optimized each sing...

Page 5: ...tayed in the warehouse 15 C 35 C where it s dry clean shade and well ventilated The battery should be stored in 50 SOC during transportation The battery need to be charged every 6 months if out of use...

Page 6: ...stop using and take it out from device If the battery leaks and get into the eyes or skin do not wipe instead rinse it with clean water and see doctor immediately Please far away from children or pet...

Page 7: ...not maintained within the specified ranges the life expectancy of the battery may be shortened or the device in which the battery is used may be damaged by electrolyte leakage If the discharge time is...

Reviews: