background image

3. Test Condition

3.1 Standard Test Conditions

3.1.1 Unless otherwise specified, all performance tests is required conducted at temperature 25°C±2°C,                   
         Humidity less than 45% ~ 75% RH.
3.1.2 Unless otherwise specified, the tested product is required unused within two month after outgoing.

NO.

Items

Description 

Length: 483.5±3mm

Width:   170±3mm

Height:  241±3mm

Dimension

Self-discharge rate

Operating Temperature 

Approx: 24.5±1.5Kg 

Charging

0~45°C

Residual capacity

≤3%/month; ≤15%/years

16

17

18

Weight

Discharging

-20~60°C

Recommended operating temperature

15°C~35°C

Reversible capacity

≤1.5%/month; ≤8%/years

Storage Temperature & Humidity Range

Less than 1 month

-20°C~35°C

45% RH

~75

% 

RH 

19

Less than 3 months

-10°C~35°C

45% RH

~75

% 

RH 

Recommended storage environment

:

15°C~35°C

45% RH

~75

% 

RH

15

Long time storage: 

If the battery need be stored for a long time, the voltage should be 13.2V (50% SOC), and stored in the 

condition as storage proposal. It need at least one charge & discharge cycle every six months

Standard discharge current

80A

11

Maximum discharge current

100A/ withstand 30min @Battery initial Temp 25±5°C

12

Pulse discharge current

Withstand the 350A/3s

13

8.0V

14

Discharge cut-off voltage

02

www.upowerbatteries.com

NA

-12Li200BL

** Siguiendo la normativa estricta de la industria naval en materias de interconexión eléctrica y salud

Reviews: