10 l/min = 0.65 - 0.85 bar
•
12 l/min = 0.68 - 0.88 bar
•
15 l/min = 0.70 - 0.90 bar
•
17 l/min = 0.75 - 0.95 bar
•
19 l/min = 1.00 - 1.20 bar
Performance curves and return temperatures
with 40 plates
Cold water warming 35 K (10-45 °C)
DI0000088
1200
200
300
400
500
600
700
800
900
1000
1100
100
0
5
10
15
20
25
65 °C
50 °C
55 °C
60 °C
70 °C
75 °C
80 °C
85 °C
A
C
B
D
Item
Description
A
Primary heating demand in litres/hour (l/h)
B
Primary heating supply temperatures
C
Tapping capacity in litres/minute (l/min)
D
Max range
Tapping capacity 35 K (10-45 °C)
DI0000090
40
35
30
25
20
15
10
5
0
5
10
15
20
25
50 °C
55 °C
60 °C
65 °C
70 °C
75 °C
80 °C
85 °C
A
B
Item
Description
A
Return temperature °C
B
Tapping capacity in litres/minute (l/min)
Cold water warming 40 K (10-50 °C)
DI0000089
1200
200
300
400
500
600
700
800
900
1000
1100
100
0
5
10
15
20
25
55 °C
60 °C
65 °C
70 °C
75 °C
80 °C
85 °C
A
C
B
D
Item
Description
A
Primary heating demand in litres/hour (l/h)
B
Primary heating supply temperatures
C
Tapping capacity in litres/minute (l/min)
D
Max range
Tapping capacity 40 K (10-50 °C)
DI0000091
40
35
30
25
20
15
10
5
0
5
10
15
20
25
A
B
55 °C
60 °C
65 °C
70 °C
75 °C
80 °C
85 °C
Item
Description
A
Return temperature °C
B
Tapping capacity in litres/minute (l/min)
32
|
Combi Port Base
|
Installation and operation manual