Quick setup
Initial configuration via console connection
To configure the Uplogix appliance via the console port, connect directly to the console port on
the front of the appliance. This port may be labeled console or 10101. The configuration
options available via the keypad are also available through the command line. These are
described below.
Open a connection to the appliance using a terminal client on your computer. Supported
terminal clients include:
Windows HyperTerminal
ZTerm (Macintosh OS X)
Minicom (Unix/Linux)
The default console connection settings are 9600 baud, 8 data bits, 1 stop bit, no parity. For
best results, set your terminal emulator to use ANSI encoding.
Note:
The Uplogix 430 does not use flow control. If you use HyperTerminal, you must disable
flow control when configuring the session.
After you connect to the appliance, you will be prompted for a username and password. The
default username is
admin
and the default password is
password
. Usernames and passwords
are case-sensitive.
Note:
Some settings shown in the examples may be unavailable on your appliance.