UC-350E+ Encoder User’s Manual
20
3.1 Ip Out Enable 01/01
[ Y ES ] NO
x
3.2.3.2 IP out Address Setting
When IP output mode has been set to “ENCODER” user can enter IP output interface
address. If the output mode has been set to “MPTS” then configuration in this field will
have no effect.
3.2 Ip Out A ddress
224.002.002.002
3.2.3.3 IP output Port Number Setting
This sub-menu will allow the user to select the TSIP output port. Unit output must be set
to ‘Encoder’ (sub-menu 3.2.3.6) rather than MPTS for this function to work.
3.3 Ip Out Port
02001
3.2.3.4 Trans Stream ID Setting
This sub-menu will allow the user to select the Trans Stream ID.
3.4 Trans Stream ID
00000
3.2.3.5 Output Stream
This sub-menu will allow the user to set the total (aggregate) Output Stream Bitrate. This
value should be big enough to contain Video, Audio and Overhead data.
3.5 Output Stream
040.000Mbps