background image

nugget font

Using the Function Keypad

25

Using the Function Keypad

The T2455 terminal has a function keypad below the screen that has these keys:

h Display contrast key

F1 through F10 function keys

 Function Left key

f Suspend/Resume key

If your application can receive all data from only scanned bar codes and function keys
(F1 through F10), you can use the T2455 without a keyboard.

Using the Keyboard

The T2455 accessory keyboard is easy to use. Characters, symbols, and functions are
printed in four places on or above the keys. The keys are also color-coded to make it
easier to remember key combinations.

Position on the Keyboard

Color

To Type the Character

Middle of the key or centered
above the key

Grey

Press the key.

Left side above the key

Orange

Press the orange 

 key, then the key.

Centered above a numeric key

Green

Press the green 

 key, then the key.

Right side above the key

Blue

Press the blue 

 key, then the key.

Summary of Contents for Intermec TRAKKER Antares 2455

Page 1: ...TRAKKER Antares 2455Vehicle MountTerminal P N 067359 001 Getting Started Guide...

Page 2: ...is not to be released reproduced or used for any other purpose without written permission of Intermec Information and specifications in this manual are subject to change without notice 1998 by Interm...

Page 3: ...3 Installing the Keyboard 14 Attaching the T2455 to the Mounting Bracket 16 Installing and Connecting the DC Power Supply 18 Attaching a Scanner 19 Connecting to Serial Devices 20 Charging the Backup...

Page 4: ...nugget font...

Page 5: ...the access points and DCS 300 or directly through the access points The T2455 also has a serial port to communicate with other devices via RS 232 serial communications Note The T2455 will communicate...

Page 6: ...applications 750K flash drive to store user applications and files Scanner port to attach a laser scanner Serial port for RS 232 communications with other RS 232 devices T2455 Options These options ar...

Page 7: ...al 2 Antenna 3 Mounting bracket 4 Getting started guide and safety supplement 5 Mounting bracket hardware 6 T2455 DC power supply cable 7 Keyboard overlay When you remove the terminal from its box sav...

Page 8: ...useful when you have the terminal connected to your PC to develop applications Keyboard The alphanumeric keyboard Part No 067028 supports a subset of the keys that are available on a PC AT keyboard Th...

Page 9: ...the function keypad below the screen for F1 F10 function keys 2455G 003 2455G 004 Mount the T2455 and an accessory keyboard as a single unit on the vehicle Attach an accessory laser scanner to input b...

Page 10: ...keyboard onto the T2455 or the vehicle optional Install the T2455 into the mounting bracket Install and connect the DC power supply Attach a scanner Connect to serial devices Fully charge the backup b...

Page 11: ...to one of the DC power supply kits 10 to 36 VDC or 15 to 96 VDC or to connect the AC power supply when operating the terminal from the desktop mounting stand You must have a power supply connected to...

Page 12: ...your Intermec sales representative for information about and a list of Intermec approved accessory antennas for the T2455 Caution Make sure all components with antennas are at least 1 foot 0 3 meters...

Page 13: ...en you mount the T2455 on metal surfaces the minimum reinforced thickness should be 10 gauge 250 inches or 3 4 mm steel Intermec recommends fastening a bolt 3 8 inch 10 mm with a flat washer lock wash...

Page 14: ...a bolt 3 8 inch 10 mm with a flat washer lock washer and nut 3 8 16 UNC 2B through each of the six holes in the mounting bracket and the mounting surface 2455G 010 Installing the Keyboard You can att...

Page 15: ...ehicle For help see the TRAKKER Antares 2455 Keyboard Installation Guide 5 Unplug the rubber plug from the Keyboard port on the terminal 6 If you are using a PC AT keyboard connect the Intermec keyboa...

Page 16: ...late 2455G 012 3 Place the terminal between the arms of the mounting bracket If the keyboard is attached to the T2455 the curved arms of the mounting bracket must point away from you 4 Insert the two...

Page 17: ...Bracket With a Keyboard 2455G 014 T2455 Shoulder screw Lock washer Washer Knob 7 Periodically inspect the knobs on the mounting bracket to make sure they are still tight Check the mounting bracket for...

Page 18: ...es 2 Connect the fused power cable to the vehicle battery or terminal block 3 Mount the DC power supply 4 Connect the power supply input cable to the power supply 5 Install terminators on the power su...

Page 19: ...port on the terminal 2 Insert the scanner cable connector straight into the Scanner port on the terminal The icon on the scanner cable connector should align with the same icon on the back of the T24...

Page 20: ...plug from the COM1 port on the terminal 2 Insert the RS 232 adapter cable connector straight into the COM1 port on the terminal The icon on the RS 232 adapter cable connector should align with the sa...

Page 21: ...supply that is connected to the vehicle battery or to the AC power supply and a powered electrical outlet 2 Let the power supply charge the backup battery for 14 hours to fully charge the backup batt...

Page 22: ...or a terminal emulation TE application welcome screen appears For example 1996 01 01 12 00 00 2455G 022 Intermec TRAKKER Antares 3270 Terminal Emulation Version 5 X Note On a T2455 loaded with termina...

Page 23: ...ocol options to communicate with other devices UDP Plus TCP IP The T2455 ships with only one of these RF network protocols To configure the T2455 to use RF communications 1 Configure the Model 200 Con...

Page 24: ...rk parameters on the T2455 To configure the terminal 1 Press or scan this bar code to access the TRAKKER Antares 2400 Menu System Enter Test and Service Mode The Main Menu appears 2455G 026 2 Choose t...

Page 25: ...455 without a keyboard Using the Keyboard The T2455 accessory keyboard is easy to use Characters symbols and functions are printed in four places on or above the keys The keys are also color coded to...

Page 26: ...a sample application You can develop your own client server application for the T2455 and then download the application to the terminal Intermec has two development tools that you can use to create ap...

Page 27: ...sories 151X laser scanner cable 6 feet Part No 066845 151X laser scanner cable 25 feet Part No 067540 1550 laser scanner cable 6 feet Part No 067541 1550 laser scanner cable 25 feet Part No 067542 155...

Page 28: ......

Reviews: