![UNMAK UKY/Y 100 User Manual Download Page 16](http://html1.mh-extra.com/html/unmak/uky-y-100/uky-y-100_user-manual_1059766016.webp)
P a g e
| 15
Hot Water Boiler with Steel Body, Automatic Fuel Feed Operation and Maintenance Manual
ÜKY/Y-KB Boiler Features
1. Fire pot
7. Fan clack
13. Upper cover
19. Fill/discharge
2. Auger
8. Hopper
14. Lower cover
20. Fan
3. Gear box
9. Hopper sieve
15. Outlet to radiators
21. Ash cleaning auger
4. Control box
10. Hopper cover
16. Return from radiators
22. Ash container
5. Flue
11. Chimney hood
17. Safety outlet
6. Flue pipes
12. Motor protection
18. Safety inlet
1.
Fire pot: Consists of two nested containers. The fuel is driven by the spiral from the incoming
chamber, blowing the fan out. The fan air and fuel meet above the ladle.
2.
Auger: It is a spiral twist, which is the shaft in the middle of the hopper that supplies the fuel
into the hearth. The fuel supply standby settings are settings for the helix operation.
3.
Gear box: Used with motor. It is used to increase the power by decreasing the speed of the
engine. Geared motor gives the movement of the auger.
4.
Control box: It is the electronic box that activates the boiler. It controls when the gear unit,
the motor, the pump will stop and when. The temperature values that you read while the
controller is active.
5.
Flue: It is the boiler section that throws out the toxic gases inside the boiler with the chimney
mechanism to be connected. The biggest factor in the good burning of the boiler
6.
Flue pipes: It is the way the burning inside the boiler is sent to the chimney. Fumes from the
flame reach the chimney through the pipes.
7.
Fan clack: When the fan is stopped when there is no burning, it is the mechanism used to
prevent air from entering. The metal cover inside the flap prevents the air intake from falling
automatically when the fan air does not pull.
8.
Hopper: This is where the fuel is stored. The capacity to be taken according to the fuel size
varies.