ÜKY/DUO Boiler User Manual
SAFETY PRECAUTIONS
Electrical installation of this product must be done by qualified personnel in
accordance with the explanations given in this manual and applicable local or
national regulations.
THIS PRODUCT MUST BE CONNECTED TO THE ELECTRICITY WITH EARTH LINE!
The boiler must be connected to a chimney in accordance with the specifications specified in the user
manual and the relevant regulations. The chimney must provide the traction value required by the
connected boiler. The boiler must not be operated without a flue connection and there must be
sufficient traction for combustion. The boiler should not be operated in the chimneys where
sufficient traction is not provided. Any malfunctioning electrical installation in the place where the
boiler is installed should be removed.
In case of changing the boiler in the boiler rooms,
the old boiler must be removed or disconnected
with the chimney and the cut must be sealed and
insulated. Under no circumstances should more
than one boiler be connected to the same
chimney. The cylindrical chimney can be passed
through the chimney in the figure.
Smoke shafts should not be placed on the outer wall of the building unless there is a technical
requirement. The wall thickness of the chimney walls should not be less than the thickness of a brick.
Hollow brick and briquette should never be used in chimney construction. It should be plastered
inside and outside and cylindrical pipe inserted into the rectangular chimney.
It should be ensured that fresh air always enters the area where the boiler is installed. The
dimensions mentioned in the guide should be taken as reference in this regard. The boiler must not
be installed in any place directly connected to the living areas or to such a place. To reduce the risk of
calcification and corrosion in old and new installations, the instructions given in the relevant section
of this manual should be followed by the installer installing the boiler. In particular, if the boiler is
connected to an old installation, it is necessary to completely clean the waste inside the installation
before installation. The installation should be washed several times.
Avoid excessive fuel loading into the boiler and the suitability of the feeding-waiting settings given in
the user manual should be checked. These settings, which indicate the working and stopping time of
the reducer, the chimney features (traction difference, etc.) to which the boiler is connected,
ambient conditions, the thermal comfort requirement of the space, the insulation of the space, etc.
varies depending on many parameters. When the settings given in the catalog are given to operate at
a lower power than they are given for the boiler to operate at maximum power, the settings are;
burning should be done by observing. Making adjustments to prevent unburned coal from falling
down from the ladle will be appropriate for both boiler efficiency and economy.