ÜKY/DUO Boiler User Manual
All electrical and water installations must be done by authorized plumbers, in accordance with any
applicable legal and technical rules, approved by the relevant legal entities.
The fuels to be burned in the boiler should be kept in a way to maintain a distance of at least 800 mm
from the boiler. It is recommended to store fuels in a separate location.
Boilers should be installed on a concrete base at a height of 10 cm from the floor in order to protect
from water moisture and solid fuel from ash dust. The concrete base prevents the fan from
absorbing fuel or ash dust on the ground.
Laying the mounting place with tiles and tile stones makes cleaning easier.
It is inconvenient to keep flammable, burning and easily flammable substances in the boiler
room.
Installation location dimensions:
The boiler room should be sized to provide the minimum dimensions given in the picture below.
While placing the boiler, it is necessary to leave sufficient distance for the fuel to be added to the
bunker easily, the reducer and the shaft under the bunker can be easily removed, and the service can
work comfortably.
The boiler room must be of a size to provide the
minimum dimensions given in the picture below.
When the boiler is placed, it can be done easily to
add to the hopper, the reducer and shaft
underneath the hopper can be easily removed,
enough distance should be left for the service to
work comfortably.
Dimension A: 60 cm greater than the opening of
the boiler door;
Measure B: Select the spindle removal distance.
If the above measurements are observed, a minimum of 8 m3 of volume requirement in the
regulations is ensured.
There should be no faulty and unsafe power lines in the boiler room.
The 230 V electrical connection from the control panel must be connected to the
mains via the W automaton.