background image

4

4-5. 3,5 mm/RCA – LINE/Input 1 & 2 – Unbalanced line inputs

 

LINE 1/Input 1 – Controlled by Vol 1 volume control  

LINE 2/Input 2 – Controlled by Vol 2 volume control

 

Note:

 With Auto Level activated the Volume level controls are disabled.

6.  Indicator Lights switch – ”ON/OFF”
7.  Header DC input/output

 

24 VDC – Connection of external 24VDC supply voltage. 

Note:

 AC adapter is not 

connected. 

12 VDC – Power supply to external emitter panel  

8.  DC power supply input 

 

Note

: Univox supplied power adapter only.

9.   RF Out – BNC jack

 

Modulated HF signal output to expansion units or additional emitter panels.  

10.  Channel/Frequency Selection toggle switch

 

Select the transmission frequency by pressing the button repeatedly.

 

2.3 MHz – Left LED indicates amber 

2.8 MHz – Right LED indicates green 

Stereo transmission, 2.3 MHz Left and 2.8 MHz right – both LEDs, amber and green 

indicates

11.  Automatic Level Control (ALC) switch – ”OFF/Auto”

 

“OFF” – ALC disabled - LED off. Use level volume controls 

(13)

 to adjust the input 

level. “Auto” – ALC enabled - LED indicates green. The unit is equipped with automatic 

adjustment of the audio level – recommended setting. 

12.  Phantom Power (12V) switch – ”ON/OFF”  

Green LED = ON

13.  Volume controls 

 

Input level adjustment if Automatic level control 

(11)

 is disabled.  

Volume 1 – XLR or Line/Input No.1  

Volume 2 – Line/Input No.2  

Indicator LED’s for each input: 
 

Green

 – nominal audio signal strength 

 

Amber

 – approaching audio signal clipping. Indicators light up when the  

 

input signal level is 6dB below clipping.   

 

Red

 – audio signal clipping input, approaching distortion.  Adjust the   

 

input level so LED flickers red occasionally, indicating audio peaks.

Summary of Contents for IR 1411

Page 1: ...User Guide Univox IR 1411 Infrared Transmitter Part no 650300 ...

Page 2: ...ge coverage up to 600m2 with a single unit Univox IR 1411 provides wireless assistive listening with supreme audio quality With single mono or dual channel stereo operation on 2 3 and 2 8 MHz carrier frequencies the unit is ideal for applications where information security and overspill control are of importance Please read this user guide carefully before installation and use of this product Incl...

Page 3: ...h Select between XLR 1 or 3 5 mm RCA 4 5 inputs Mic balanced XLR Mic or Line 1 level input with 12 V Phantom voltage 12 Line unbalanced RCA or 3 5 mm line level inputs mono or stereo 1 XLR Balanced Mic or Line input 2 Power Save mode switch 3 Mic Line switch 4 3 5 mm Line 1 2 Unbalanced line input 5 RCA Line 1 2 Unbalanced line input 6 Indicator Lights switch ON OFF 7 Header DC input output 8 DC p...

Page 4: ...eft LED indicates amber 2 8 MHz Right LED indicates green Stereo transmission 2 3 MHz Left and 2 8 MHz right both LEDs amber and green indicates 11 Automatic Level Control ALC switch OFF Auto OFF ALC disabled LED off Use level volume controls 13 to adjust the input level Auto ALC enabled LED indicates green The unit is equipped with automatic adjustment of the audio level recommended setting 12 Ph...

Page 5: ...2 Connect the supplied power adapter to the DC supply input 8 and set Power switch to ON The red LED indicates power connection 3 Set Audio Level Control ALC switch 11 to Auto green LED is lit Input level will be adjusted automatically recommended setting Note Setting the switch in OFF position will disable ALC green LED is off Audio level for each input must be adjusted manually by Volume control...

Page 6: ...e Control LEDs are indicating red occasionally if the unit is transmitting correctly Make sure the transmitter and receiver are operating at the same channel frequency for best performance Stereo setting is highly recommended Verify that both amber and green LED at the transmitter are lit and receivers channel switch is set in S mode Stereo Make sure the receivers are in the line of sight and rang...

Page 7: ... univox eu support Safety The installer is responsible for installing the product in a way that may not cause risk of fire electrical malfunctions or danger for the user Do not cover the unit or the power adapter Only operate the unit in a well ventilated dry environment Do not remove any covers as there is a risk of electric shock Please observe that the product warranty doesn t include faults ca...

Page 8: ...ximum input level 20dBm 7 75V Input 2 Line 1 Line 2 Unbalanced Line Stereo Input Two 3 5mm connectors Input 3 RCA IN Unbalanced Line Stereo Input Two RCA Phono connectors Input 10dBu Nominal 14dB headroom Impedance 10kΩ Indicators Green LED nominal range of audio level Red LED audio peak indicator approaching audio distortion Output connection BNC x 1 RF Output Voltage Approx 750 mVrms 2Vpp Output...

Reviews: