23
In Pow Amp
Connection Type:
RCA (Phono)
Input level:
Approximately 0.5V
Out Pre Amp
Connection Type:
RCA (Phono)
Output Level:
Approximately 0.5 V
Output signal after low pass filter and AGC. Can be used as the input to other loop drivers.
Loop Output
Connection Type:
Screw terminal (4 connections)
Use the two outer connections for a single turn loop (see page 17).
The two inner connections (center) are used as a shorting bar for configuring a 2-turn loop
with twin core cable (see page 17)
PLS-X1
PLS-X3
PLS-X5
Max Voltage
22 Vpp
31 Vpp
36.5 Vpp
Max Current
4.7 A RMS
6.5 A RMS
9.5 A RMS
Supplementary Outputs
Connection Type:
Phoenix screw terminal (6 connections)
Connection
Type
Function
Specification
1
Audio output
Monitor speaker
10 W IC power chip, 4-32 Ω
2
Ground
Ground
Ground
3
DC power
supply
Auxiliary power
supply
19-36 V, 100 mA DC
4,5
LED driver
Indicates output
current = 0dB LED
Suitable for direct connection of LED or
external diagnostic test
5,6
LED driver
Indicates input
signal is > -6 dB
Suitable for direct connection of LED or
external diagnostic test