PROCESSING PRODUCT
Before processing product, please review the plate usage chart on page 8, and please note that the feed
plate is equipped with an adjusting screw and jam nut. This assembly should be adjusted until there is no
chance of the feed plate coming in contact with the cutting surfaces. If the feed plate comes in contact
with the rotating cutting surfaces, both components will be damaged.
TO PROCESS PRODUCT:
Connect the VS2000 electrical power supply cord, and turn the unit on.
Lift the feed plate to expose the processing plate unit and drop product into the feed hopper. Keep
hands and fingers out of the hopper. With the feed plate, gently push the product into the rotating plate
unit.
If you experience a problem in processing, shut the VS2000 power unit off and refer to the trouble
shooting guide on page 14.
DISMOUNTING AND DISASSEMBLY
FOR CLEANING AND MAINTENANCE
DISMOUNTING:
Make sure that the VS2000 is turned off and its electrical power supply cord is disconnected. Loosen
the thumb screw and slide the VS9 from the PTO hub. Set the VS9 on a stable working surface.
DISASSEMBLY:
To disassemble the VS9 for cleaning or maintenance.
Unlatch the front housing and swing it toward you.
Swing the feed plate all the way up and slip it off the front housing and set it aside.
Lift the front housing from the pivots and set it aside.
Remove the processing plate unit
To disassemble the processing plate units, follow the assembly instructions on page 4 and 5 in reverse
order.
Page 12