Gas burning pizza brickoven
R-001 100518
Page 27 of 33
8.1.7 Setting AUt Levels
When selecting flame levels like described in 8.1.4 if SET button is pushed within 5
seconds after AUt is shown on the display, you can access the temperature regulation
mode.
All 3 digits on the display will be blinking and you will be able to set desired temperature
using
– or + button to increase or decrease the displayed value. Keeping – or + buttons
pushed for a longer time will speed up the selection cycling faster between values.
If you change the value, you can record it by pressing SET button to exit selection
immediately, or wait 5 seconds: new value will be saved in any case.
8.1.8 Burner Safety Block
Whenever burner faces a forced shutdown due to flame not being correctly detected by
the safety probe (i.e. gas not reaching the oven) the burner will be blocked and will need to
be manually rearmed. This status will be indicated on the display by alternating
“bLc” and
“rSt” codes, in order to suggest the operator to proceed with the reset and rearm
procedure.
To reset the error keep the red reset button pressed for 2 seconds and wait for the display
to go back to its standard working procedure. If the problem causing the block is solved
(i.e. opening a gas knob that was accidentally closed) the oven will be back to its normal
functionality. If the problem still persists the burner will block again, reporting that the issue
was not solved.