The UNIVEX slicer is designed to meet the cook's demand for an efficient, sturdy slicer. The 

UNIVEX slicer will give unfailing performance over a period of years, when operated and 

maintained according to instructions contained herein.

START/STOP SWITCH

The slicer is started by pushing the ON/OFF switch (Overview [1]). A indicator light (Overview [1]) is 

provided to indicate when the slicer is turned on.

AUTOMATIC MODE:

Be sure to set your slice thickness by turning the Slice Adjust Knob (Overview [12]) first before 

setting the slicer to automatic. To switch the slicer to automatic mode, simply turn the Automatic 

Selector Knob (Overview [13]) from Manual to Auto then press the Start Switch. The slicer will turn 

on and the carriage will begin moving back and forth. The desired speed of the motion can be set 

by adjusting the Variable Speed Knob (Overview [14]). Simply turn the Automatic Selector Knob 

back to Manual to end the automatic feature or shut the slicer off.   

SLICE ADJUSTMENT

Warning

: Dial-type knob adjustment (Overview [12]) allows for slice thickness ranging

from paper thin up to .875". Dial graduations allow you to precisely set up specific slice thickness 

for various needs. Please note that the numbers labeled on the slice adjustment knob are for 

reference only and do not indicate any specific unit of measure. When not in use, always return 

knob back to its fully closed position (beyond "0") so that the knife edge is not exposed.

POSITIVE HOLD CARRIAGE

Caution:

 A last slice gravity feed grip Overview [3]) is provided which can be locked out

of the way when not required. Do not use this last slice device to work the carriage back and forth. 

Use only the carriage arm handle (Overview [11]). Always make sure the carriage is 

positively secured to the slicer by checking to see that the carriage arm knob (Overview [10]) 

is fully tightened.

PROTECTIVE GUARD

Warning:

 The protective guard (Overview [5]) covers the knife edge completely except at

the forward edge where slicing will be performed. This forward edge is covered by the edge of the 

fence, but only when the slice adjustment is completely closed.The knife guard 

(Overview [6]) can be removed for cleaning by unscrewing the knife guard knob 

( Refer to p.6 Figure 2 [2]). For safety, keep the knife guard on at all times except when cleaning. 

Never operate the slicer with the knife guard removed.

OPERATION INSTRUCTIONS

Page 5

Summary of Contents for 8713S

Page 1: ...icer Operators Manual 10 2016 ED2 Persons under the age of 18 are not permitted to operate or have accessibility to operate this equipment per U S Dept Of Labor employment standards administration fact sheet No ESA91 3 ...

Page 2: ...L BE INVLOVED WITH YOUR NEW UNIVEX SLICER MUST READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE ATTEMPTING TO OPERATE THIS SLICER WE APPRECIATE YOUR COOPERATION AND YOUR BUSINESS SHOULD THERE BE A QUESTION OR IF WE CAN BE OF FURTHER ASSISTANCE PLEASE CALL US 1 800 258 6358 ATTENTION Page 1 ...

Page 3: ...leaning Instructions p 6 7 7 Sanitizing Instructions p 8 9 Lubrication Instructions p 10 10 Inspection of Seals p 11 11 Slicer Wiring Diagram p 12 12 Warranty Information p 13 a Inspection b Installation c Important Safety Warnings a Start Stop Switch b Automatic Mode c Slice Adjustment d Positive Hold Carriage e Protective Guard 8 Sharpening Instructions p 9 Page 2 ...

Page 4: ... Slice Device 4 Sharpener Assembly 5 Protective Guard 6 Knife Guard 8 Carriage 9 Carriage Arm 10 Carriage Arm Knob 11 Carriage Arm Handle 12 Slice Adjustment Knob 1 2 3 4 5 6 7 8 9 10 11 12 13 14 7 Adjustment Spacer 13 Automatic Manual Selector Knob 14 Variable Speed Knob Overview Page 3 ...

Page 5: ...ht is considered optimum when the carriage handle Overview 11 of the slicer is at approximately the height of the operator s elbow when standing Important Warning Caution Before making electrical connections CHECK the specifications on the nameplate to make sure that they agree with those on your electrical service A grounding type three terminal plug is provided for safety If you do not have a ma...

Page 6: ...875 Dial graduations allow you to precisely set up specific slice thickness for various needs Please note that the numbers labeled on the slice adjustment knob are for reference only and do not indicate any specific unit of measure When not in use always return knob back to its fully closed position beyond 0 so that the knife edge is not exposed POSITIVE HOLD CARRIAGE Caution A last slice gravity ...

Page 7: ...ndle Loosen and remove the black handle Figure 1 9 and set aside d Carriage Arm Loosen the Carriage Arm Knob Figure 1 8 and set aside for cleaning Pull straight upwards on the Carriage and Arm Figure 1 7 and set the Carriage Assembly aside e Slice Adjustment Knob and Automatic Knob Remove screws located on front of Slice Adjustment Knob Figure 1 10 and Automatic Knob Figure 1 11 and set aside Pull...

Page 8: ... water and a mild detergent 5 Wash the front and rear of the Knife Figure 6 2 and Knife Scraper Figure 7 with warm water and a mild detergent using extreme CAUTION around the blade Carefully remove the Knife Scraper as seen in Figure 8 and clean around the Knife s edge as shown in Figure 9 with warm water and a mild detergent applied to a soft cloth 6 Wash the Slicer Body Figure 6 3 with warm wate...

Page 9: ...Section 4 501 114 Manual and Mechanical Warewashing Equipment Chemical Sanitation Temperature pH Concentration and Hardness of the FDA Food Code Chlorine Sanitizer Solution A chlorine sanitizer solution shall have a minimum temperature based on the concentration and pH of the solution listed in the following chart taken from section 4 501 114 of the FDA Food Code Minimum Concentration mg L 25 50 1...

Page 10: ...Dial Figure 1 12 to beyond 0 This will ensure that the blade edge is not exposed to the operator 4 Move the carriage all the way to the start position closest to the operator 5 Loosen the sharpener locking pin Figure 10 1 then lift and rotate the sharpener 180 Lower the sharpener so that the blade is between the 2 stones and resecure with the sharpener locking pin 6 Turn the slicer on and push the...

Page 11: ...r free operation and movement of related parts as well as for excessive wear and looseness of various parts Be sure to check all handles and knobs for tightness Never use any type of vegatable cooking spray or oil as lubrication as this will cause damage to your slicer Lubrication Instructions A Clean and apply mineral oil weekly Remove the 4 bottom cover screws to gain access to the slice adjustm...

Page 12: ...move the slicer from service and contact an authorized service agency or Univex Full thorough inspections should be conducted not exceeding 6 month periods and is recommended to be performed by an authorized service agency However as the regular operator of the machine seals should be reviewed during normal daily cleaning and reported upon if found to be worn Refer to the below figure 14 for seal ...

Page 13: ...WITCH GND L N N O MICRO SWITCH MOTOR INVERTER M 3MOTOR INVERTER 220 50 60 3 3010163 N O MICRO SWITCH COVER BLADE OPTION VARIABLE SPEED INTERNAL VIEW INVERTER SCHNIDER TEATV12H018F1 IN 120 VAC 1PH OUT 220 VAC 3PH 1 4A COM AI1 5V BLACK RED WHITE R1A R1B R1C A01 GND GND LI3 LI4 24V LI1 LI2 COM L0 R L1 S L2 GDN U V W RESISTANCE 1000 OHM FOR 2 2 KOhms POTENTIOMETER RESISTANCE 5600 OHM FOR 10 KOhms POTE...

Page 14: ...the hours of 8 00 a m and 5 00 p m local time Monday through Friday Univex will not cover overtime charges of any kind Please call the Univex Warranty Service Department at 800 258 6358 to report any warranty claims before arranging repair or attempting to return the unit to Univex Corporation Damages incurred in transit or incurred because of installation error accident alteration or misuse are n...

Reviews: