INSTALLATION AND OPERATION

INSTALLATION INSTRUCTIONS: CAUTION!! READ CAREFULLY.

CAUTION: THIS UNIT IS SEALED. THE COVER IS NOT REMOVABLE

!

A mounting plate is provided on the back of the alarm.

Remove the mounting plate from the back of the alarm by holding the mounting plate and twisting the
alarm in the direction indicated by the "OFF" arrow on the alarm cover.

To ensure aesthetic alignment of the alarm with the hallway or wall, the "A" line on the mounting plate
must be parallel with the hallway walls when ceiling mounting or horizontal when wall mounting
(See Steps A and B).

After selecting the proper carbon monoxide alarm location as described in Figure 1, attach the
mounting plate on the wall. Be sure the "UP FOR WALL MOUNTING" text and arrow are facing up.
Use the screws and anchors provided to secure the mounting plate.

To initially activate the 9 Volt battery and alarm, pull and remove the plastic pull-tab. Discard the pull-
tab.

Install the battery in the correct orientation as noted on the inside of the battery door. The alarm will
beep once, indicating proper battery installation.

CAUTION! IF NO BATTERY IS INSTALLED, THE BATTERY DOOR WILL NOT CLOSE AND THE UNIT
WILL NOT ATTACH TO THE MOUNTING BRACKET.

Alignment marks are provided on the edge of the trim plate and the alarm. After installing the mounting
plate, place the alarm on the mounting plate with the alignment marks lined up. Twist the alarm in the
direction indicated by the "ON" arrow on the alarm cover (See Step D) until it locks in place.

USING TAMPER RESISTANT LOCKING PIN: 

To make your carbon monoxide alarm tamper resistant, a

locking pin has been provided in the bag with the screws and anchors. Using this pin will deter children
and others from removing the alarm from the mounting plate. To use the pin, insert it into the hole in the
side of the alarm after the alarm has been installed on the mounting plate (See Figure 5). Note the
tamper resistant pin will have to be removed in order to change the battery. This can be done easily
with long nose pliers. Using the long nose pliers, pull the pin out of the hole. It is now possible to remove
the alarm from the mounting plate.

Test alarm immediately following installation

 and weekly for proper operation by pushing the

test button approximately three seconds until a short beep is heard. Release the button. The alarm will
then test itself for proper operation and the red LED indicator will flash 3-4 times, the alarm will sound
an alarm pattern of 4 beeps with the red LED on, a 5 second quiet period and another 4 beeps with the
red LED on. Then, the unit resets with a final red LED flash. The alarm then resumes normal operation.

Page 5

FIGURE 4

FIGURE 5

Summary of Contents for CD-9000

Page 1: ...from ANY source of combustion CAUTION This alarm will only indicate the presence of carbon monoxide gas surrounding its sensor Carbon monoxide gas may be present in other areas WARNING This product is intended for use in ordinary indoor locations of family living units It is not designed to measure compliance with Occupational Safety and Health Administration OSHA commercial or industrial standard...

Page 2: ...nt serviced immediately Note any combustion equipment not inspected by the technician and consult the manufacturers instructions or contact the manufacturer s directly for more information about CO safety and this equipment Make sure that motor vehicles are not and have not been operating in an attached garage or adjacent to the residence INSTALLING THE ALARM FOR RESIDENTIAL USE LOCATION One of th...

Page 3: ...es or similar contaminants are used Excessive spillage or reverse venting of fuel burning appliances caused by outdoor ambient conditions such as Wind direction and or velocity including high gusts of wind Heavy air in the vent pipes cold humid air with extended periods between cycles Negative pressure differential resulting from the use of exhaust fans Simultaneous operation of several fuel burni...

Page 4: ... In multi family buildings each residential unit should have detectors installed as previously indicated When properly located installed and maintained this CO alarm is designed to provide early warning of developing poisonous CO conditions at a reasonable cost This alarm monitors the air and when it senses CO it activates its built in alarm It can provide precious time for you and your family to ...

Page 5: ... on the edge of the trim plate and the alarm After installing the mounting plate place the alarm on the mounting plate with the alignment marks lined up Twist the alarm in the direction indicated by the ON arrow on the alarm cover See Step D until it locks in place USING TAMPER RESISTANT LOCKING PIN To make your carbon monoxide alarm tamper resistant a locking pin has been provided in the bag with...

Page 6: ...nd the red LED indicator to flash approximately every 30 40 seconds for a minimum of 7 days when the battery gets low Replace the battery when this condition occurs USE ONLY THE FOLLOWING 9 VOLT BATTERIES FOR CO ALARM REPLACEMENT Alkaline type EVEREADY 522 DURACELL MN1604 GOLD PEAK 1604AU Lithium type ULTRALIFE U9VL NOTE REGULAR TESTING IS RECOMMENDED WARNING USE ONLY THE BATTERIES SPECIFIED USE O...

Page 7: ...407 Cronhill Drive Suite A Owings Mills Maryland 21117 You must include a proof of purchase receipt along with the returned product USI DOES NOT WARRANT AND SPECIFICALLY DISCLAIMS ANY WARRANTY WHETHER EXPRESS OR IMPLIED OF FITNESS FOR A PARTICULAR PURPOSE OTHER THAN THE WARRANTY CONTAINED HEREIN NO IMPLIED WARRANTY ON THIS PRODUCT CREATED BY STATE LAW SHALL EXTEND BEYOND THE TERM OF THIS WARRANTY ...

Reviews: