background image

D-301850 MCT-220 User’s Guide 

 

MCT-220 

Wireless Emergency Button 

 

User Guide 

1. INTRODUCTION 

1.1 General 

The  MCT-220  enables  people,  for  example  senior  citizens  in  their 
home  environment,  to  transmit  an  emergency  call  when  they  are  at 
some distance from their communication unit.  

1.2 Additional Features 

  Can be used for panic alarm,  when used  with a  Visonic Amber or 

PowerMax family system. 

  Can be used for X-10 devices activating when used with a Visonic 

PowerMax family system. 

  An  auxiliary  sensor  can  be  connected  to  the  MCT-220.  When  the 

sensor is in an alarm state, the MCT-220 sends an alarm message 
from its auxiliary channel.  

  Enables people to answer incoming calls when the telephone is out 

of reach, when used with a Visonic Amber family system. 

  MCT-220  button  pressing  period  -  2  seconds  or  300  milliseconds 

(selectable by an internal function selector). 

 

Figure 1 – MCT-220

 

  Supervision  signal  is  regularly  transmitted  to  the  communication 

unit. 

  In  low  battery  voltage  state,  an  alarm  message  is  sent  to  the 

communication  unit  and  the  MCT-220  button  blinks  during 
transmission. 

  Push  button  back  light  can  be  switched  On/Off  by  an  internal 

function selector. 

  Auxiliary input E.O.L /  Normally Close type can  be selected by an 

internal function selector. 

  Auxiliary  input  alarm  restore  message  can  be  enabled  /  disabled 

(selected by an internal function selector). 

  Water resistant. 

 

2. SPECIFICATIONS 

GENERAL 
Compatibility: 

Compatible  with  all  Visonic  control  panels  and 

receivers.

 

Operating  Frequencies  (MHz): 

315,  433.92,  868.95,  869.2125  or 

869.  

ELECTRICAL 
Internal Battery:

 3V battery type CR123 

Current  Consumption: 

35  mA  (during  transmission),

 

20µA  in 

standby mode.

 

Battery Life Expectancy: 

5 years (for one alarm per day) 

ENVIRONMENTAL 
Operating Temperature: 

0° to 50°C (32° to 122°F)

 

Standards:

 Designed to comply with FCC CFR 47 Part 15, UL 1637, 

Directive 1999/5/EC, EN 50131-2, Grade 2, Class II, RSS-210.

 

PHYSICAL 
Dimensions (Diameter x H):

 90 x 35 mm (3-1/2 x 1-3/8 in) 

 

Weight: 

110g (3.9 oz.)

 

Color: 

White 

Note:

 

The  manufacturer  is  not  responsible  for  any  radio  or  TV 

interference caused by unauthorized modifications to this equipment. 
Such  modifications  could  void  the  user's  authority  to  operate  the 
equipment

Compliance  with  standards  (Europe): 

ETSI  EN  301  489-3  V1.4.1, 

EN 50130-4, & A1: & A2, EN 300 220-2 V2.1.2, EN 300 220-1 V2.1.1, 
EN 50131-1, Grade II, Class II, EN 60950-1 

This device complies with Part 15 of the FCC Rules and RSS-210 of 
Industry  and  Science  Canada.  Operation  is  subject  to  the  following 
two  conditions:  (1)  This  device  may  not  cause  harmful  interference, 
and  (2)  this  device  must  accept  any  interference  received,  including 
interference that may cause undesired operation. 

 

This

 

device  complies  with  the  essential  requirements  and  provisions 

of Directive 1999/5/EC of the European Parliament and of the Council 
of

 

9

 

March

 

1999

 

on

 

radio

 

and

 

telecommunications

 

terminal

 

equipment. 

 

3. PREPARATION FOR USE 

3.1 Cover Removal 

1

2

COVER

BASE

 

Figure 2 – Cover Removal 

3.2 Function Selector Setting 

The  MCT-220  has  a  4  lever  switch  (see  Fig.  3).  Each  switch  lever 
allows you to select one of two options

.

 

BATTERY

MOUNTING HOLE

FUNCTION SELECTOR

WIRING KNOCKOUT

MOUNTING HOLE

AUXILIARY INPUT TERMINALS

 

Figure 3 – Internal View 

Set  the  switches  as  desired  (see  table  1) 
prior to applying power. Use a ball point pen 
or  another  pointed  object  to  shift  the  switch 
levers.

  The  ON  position  is  indicated  on 

the switch body.

 

ON

1

2

3

4

 

Figure 4 

Function Selector

 

Table 1.

 Function Selector Description 

 

Function 

Pos. 

Selected Option 

Default

 

SW1

 

Back light ON/OFF 

ON 

Button's back light ON 

ON 

OFF  Button's back light OFF 

SW2

 

Aux. input type 
selector (*) 

ON 

Aux. input is E.O.L. (47 k

OFF 

OFF  Aux. input is N.C. 

SW3

 

Auxiliary input 
restore reports 
enable/disable (**) 

ON 

Aux input Restore events 
are reported 

ON 

OFF  Aux. input restore events 

are not reported 

SW4

 

Pressing period of 
push button  

ON 

2 seconds 

OFF 

OFF  300 milliseconds 

(*)   SWITCH SW2

 

determines whether the auxiliary input will behave 

as  a  47k

  end-of-line  (E.O.L.)  input  or  as  a  normally  closed 

(N.C.) input. 

(**) SWITCH SW3 determines whether the MCT-220 will report a restore 

event when the auxiliary input restores from an alarm condition. 

3.3 Battery Insertion 

Insert battery (see Figure 3) – Verify proper polarity. 

Caution!

 Risk of explosion if battery is replaced by an incorrect type. 

Dispose  of  used  batteries  according  to  the  manufacturer's 
instructions

.