THIS SMOKE ALARM WILL NOT WORK WITHOUT A GOOD BATTERY PROPERLY INSTALLED.
THE SMOKE ALARM SHOULD BE TESTED WHEN INSTALLED AND THEN TESTED WEEKLY
AFTER THAT.

Early warning fire detection is best achieved by the installation of fire detection equipment in all
rooms and areas of the household as follows: A smoke alarm installed in each separate sleeping
area (in the vicinity of, but outside of, the bedrooms); and, as appropriate, heat or smoke alarms in
living rooms, dining rooms, kitchens, hallways, attics, furnace rooms, closets, utility storage rooms,
basements and attached garages. Test the alarms weekly to assure proper operation.

CAUTION: THIS SMOKE ALARM IS SEALED. THE COVER IS NOT REMOVABLE

!

A mounting bracket is provided on the back of the alarm.

Remove the mounting bracket from the back of the alarm by holding the mounting bracket and twisting
the alarm.

OPTIONAL TAMPER RESISTANT FEATURE:

 There is a separate tamper resistant locking feature provided

for this model. Activating this feature deters someone from removing the smoke alarm from the mounting
bracket. The breakaway locking pin is clearly marked and molded into the mounting bracket. Refer to the
diagram.

TO ACTIVATE THE LOCKING FEATURE:

 Do not activate the locking feature until you have activated the

battery, mounted the smoke alarm to the bracket and tested the smoke alarm. Refer to OPERATION,
TESTING & MAINTENANCE instructions on Page 6.
1.

Detach the breakaway alarm locking pin from the mounting bracket.

2.

Insert the pin into the hole for the tamper resistant feature. Refer to the diagram below for correct
placement.

TO DEACTIVATE THE LOCKING FEATURE:

 To remove the smoke alarm for cleaning or servicing or to

replace the battery, you must first remove the locking pin, if it has been installed.
1.

Use long nose pliers to pull the locking pin out of the hole.

2.

It is now possible to remove the smoke alarm or replace the battery.

in areas of turbulent air such as air returns or heating and cooling supply vents, smoke alarms shall not
be located where airflow prevents smoke from reaching the alarms.

in extremely dusty, dirty or insect-infested areas. Loose particles interfere with smoke alarm operation.

in areas where temperature may fall below 40

0

F (4.4

0

C) or rise above 100

0

F (37.8

0

C).

closer than 1 foot (0.3m) from fluorescent lights, electrical "noise" and flickering may affect the alarm's
operation.

closer than 3 feet (0.9m) horizontal path from the tip of the blade of a ceiling suspended (paddle) fan.

on a poorly insulated ceiling or exterior wall (mount smoke alarm on an inside wall).

MOUNTING INSTRUCTIONS

1.

Attach the mounting bracket in the proper location on the wall or ceiling (screws and anchors provided).

2.

To activate 9 volt battery and alarm, hold the battery, pull and remove the PULL-TAB.  Confirm that the
entire PULL-TAB has been completely removed. Discard PULL-TAB.

3.

Push and twist the alarm clockwise onto the mounting bracket.

4.

See "OPTIONAL TAMPER RESISTANT FEATURE" and "TO ACTIVATE THE LOCKING FEATURE"
instructions on Page 4.

5.

The red LED will blink on every 40-45 seconds to indicate proper operation.

ALARM LOCKING PIN

ALARM BRACKET

INSERT ALARM

LOCKING PIN HERE

Page 4

Summary of Contents for 1422

Page 1: ...ion Testing Maintenance 5 QUICK FIND Alarm Originating Feature Reset 5 Cautions Warnings 5 Battery Replacement 6 Develop and Practice a Plan of Escape 6 Operational Summary 8 Warranty Back Cover MODEL 976 976L SECURITY INSTRUMENTS INC MODEL 1422 1422L READ ALL INSTRUCTIONS This smoke alarm uses an extremely small amount of a radioactive element in the ionization chamber Do not tamper with radioact...

Page 2: ...roperly locate your alarm to avoid nuisance alarms A SMOKE ALARM MAY NOT ALWAYS WARN YOU ABOUT FIRES CAUSED BY CARELESSNESS AND SAFETY HAZARDS LIKE SMOKING IN BED VIOLENT EXPLOSIONS ESCAPING GAS IMPROPER STORAGE OF FLAMMABLE MATERIALS OVERLOADED ELECTRICAL CIRCUITS CHILDREN PLAYING WITH MATCHES NATURAL CAUSES SUCH AS LIGHTNING OR ARSON FIRE PREVENTION IS YOUR BEST SAFEGUARD INSTALLING SMOKE ALARMS...

Page 3: ...rtion of the ceiling within 12 in 305 mm vertically down from the highest point Mobile Home Installation For minimum protection smoke alarms should be installed in compliance with H U D Manufactured Home Construction Safety Standards Title 24 CFR Section 3280 208 and Section 3282 For additional protection see Single Story Residence smoke alarm requirements recommendations for Existing Homes and Ne...

Page 4: ...t the pin into the hole for the tamper resistant feature Refer to the diagram below for correct placement TO DEACTIVATE THE LOCKING FEATURE To remove the smoke alarm for cleaning or servicing or to replace the battery you must first remove the locking pin if it has been installed 1 Use long nose pliers to pull the locking pin out of the hole 2 It is now possible to remove the smoke alarm or replac...

Page 5: ... ORIGINATION The QUICK FIND feature will allow you to immediately locate the originating alarm once the alarm has stopped sounding To initiate QUICK FIND press the Test Silence button on each alarm After releasing the button the originating alarm will continue to sound for 60 seconds In a non interconnected installation it is necessary to test each alarm to determine the originating alarm RESET To...

Page 6: ...er is exempt from any licensing or requirements If the smoke alarm is defective in any way do not tamper with the smoke alarm Return the smoke alarm for servicing See warranty for instructions or in warranty returns There will be a service charge for repairing out of warranty smoke alarms DEVELOP AND PRACTICE A PLAN OF ESCAPE BASICS OF ESCAPE PLAN o Make a floor plan indicating all doors and windo...

Page 7: ... by the installation of fire detection equipment in all rooms and areas of the household as follows A smoke alarm installed in each separate sleeping area in the vicinity of but outside of the bedrooms and heat or smoke detectors in the living rooms dining rooms bedrooms kitchens hallways attics furnace rooms closets utility and storage rooms basements and attached garages NATIONAL FIRE PROTECTION...

Page 8: ...temporarily remove and then replace the battery This will clear alarm origination and clear Silence mode Reset after each smoke alarm event Nuisance Alarm If there is no hazard present verify the alarm is mounted in the correct location see User s Manual AVOID THESE LOCATIONS section Reset alarm as instructed below 3 Beeps 2 second pause Repeat Silence Feature is activated by pressing and releasin...

Page 9: ... B Short circuiting the battery C Attempting to charge the battery D Subjecting the battery to excessive humidity hot or cold conditions E Altering the battery physically in any way ULTRALIFE 9 VOLT BATTERY RETURNS To return the Ultralife Battery under warranty send battery ONLY along with a note describing nature of difficulty and proof of date of purchase postage prepaid and return postage to UL...