background image

 

 
Item No. 0BL-00-010            Rev. 12/21/2017           Copyright (C) 2017, Universal Metal Industries, Inc.         Prov. 22:29         Page 6 

Drawings below show rear discharge configuration (after easy conversion).   

IMPORTANT

:  All dimensions are n/- 1/8”.  

 

 
 
 
 
BACKVIEW 

 
 
 
 
 
 
 
 
 
 
 

 
 

 
 
 

 

 
 
 
 
 
 
 
BACKVIEW 

 
 
 
 
 
 
 
 

 
 
 
 
 
 

 
 
 
 
 

 

Model # 

(No Blower) 

(1200 CFM) 

 

 

S7236CD 

S723612CD 

S7242CD 

S724212CD 

S7248CD 

S724812CD 

Model # 

(No Blower) 

(2300 CFM) 

 

 

S7254CD 

S725423CD 

S7260CD 

S726023CD 

S7266CD 

S726623CD 

S7272CD 

S727223CD 

Summary of Contents for Trade-Wind S723612CD

Page 1: ...coverage on all sides that are not protected from direct rain by an adjacent wall It is required that all duct work and roof openings be thoroughly sealed with the applicable tape and or roof sealant...

Page 2: ...T b NEVER PICK UP A FLAMING PAN YOU MAY BE BURNED c DO NOT USE WATER including wet dishclothes or towels a violent steam explosion will result d Use an extinguisher ONLY if 1 You know you have a Class...

Page 3: ...sides that are not protected from direct rain by an adjacent wall g It is also required that all duct work and roof openings be thoroughly sealed with the applicable tape and or roof sealant to preven...

Page 4: ...scharge configuration default See page 6 for dimensions relating to rear discharge option IMPORTANT All dimensions are nominal 1 8 FRONTVIEW FRONTVIEW Model No Blower 1200 CFM S7236CD S723612CD S7242C...

Page 5: ...off the 8 nuts and washers to release the other solid plate currently mounted inside the back of the unit Put in place where the other plate was top of unit and secure using same nuts and washers 6 No...

Page 6: ...wings below show rear discharge configuration after easy conversion IMPORTANT All dimensions are nominal 1 8 BACKVIEW BACKVIEW Model No Blower 1200 CFM S7236CD S723612CD S7242CD S724212CD S7248CD S724...

Page 7: ...Follow instructions carefully to ensure proper installation It is the owner s responsibility to ensure that a qualified person performs the electrical connection of this appliance The electrical inst...

Page 8: ...n performance and appearance while also ensuring safe operation The frequency of cleaning should be adjusted according to the type and amount of cooking Best results will be achieved by cleaning soile...

Page 9: ...es or reset breakers Service calls to correct faulty installation such as performance issues relating to improperly sized ducting or restrictive roof caps Universal Metal Industries Inc disclaims and...

Page 10: ...f restriction anywhere in the ventilation system will cause increased static pressure air resistance that may result in rattling vibration and air buffeting noises as well as inadequate ventilation Se...

Page 11: ...roof cap used needs to be at or above 78 5 square inches See illustrations above Never use a roof cap like the one shown in Figure 1 Instead use a style similar to the one shown in Figure 2 6 Attachi...

Page 12: ...see Drawing B In this example the hood is attached to a built out section of the wall or to a chase It is unlikely that smoke rising past the bottom of the BBQ hood will be captured by the hood Smoke...