20
Part. 14000001
Rev. 04//2021
®/™ ©2021 Unity Laundry Systems. All rights reserved.
INSTALLATION
4. Attach the external supply hoses to the ports at each of the drilled holes.
5. Secure with proper clamps.
6. Make the electrical connection as specified.
NOTE: Do not attempt to make chemical injection supply pump electrical connections to points other than those
provided specifically for that purpose by the factory.
3.8 REMOVAL OF SHIPPING BRACKETS AND DOOR CABLE - UTS40
WARNING
DO NOT REMOVE THE SHIPPING BRACKETS BEFORE PLACING
THE WASHER IN ITS FINAL LOCATION.
NEVER START THE MACHINE UP WITHOUT FIRST REMOVING THE
SHIPPING BRACKETS.
NON-COMPLIANCE WITH THIS PRECAUTION MAY CAUSE SERIOUS
PHYSICAL DAMAGES TO PEOPLE AND IRREPARABLE DAMAGES
TO THE WASHER. THE WARRANTY DOES NOT COVER THIS
INCIDENCE.
After positioning, remove the lower front and back panels and remove the four shipping brackets that were used for
transportation support. Save the shipping brackets. If the washer ever needs to be moved to another location, replace the
shipping brackets prior to moving the machine.
FRONT SHIPPING BRACKETS
REAR SHIPPING BRACKETS