19
Part. 14000001
Rev. 04//2021
®/™ ©2021 Unity Laundry Systems. All rights reserved.
3.7. SUPPLY DISPENSING
3.7.1 Manual Dosing
WARNING
Dangerous Chemicals. May damage eyes and skin. Wear eye and
hand protection when handling chemicals; always avoid direct
contact with raw chemicals. Read the manufacturer’s directions for
accidental contact before handling chemicals. Ensure an eye-rinse
facility and an emergency shower are within easy reach. Check at
regular intervals for chemical leaks.
This machine has 4 liquid chemical supply and 5 external liquid supply connections.
Pre-wash Main Wash Liquid Liquid
(LIQUID OR POWDER) BLEACH SOFTENER
IMPORTANT: Undiluted chemical dripping can damage the machine. All chemical injection supply dispenser pumps
and dispenser tubing should be mounted below the washer’s injection point. Loops do not prevent drips if these
instructions are not followed.
IMPORTANT: Failure to follow these instructions could damage the machine and void the warranty.
3.7.2 External Dosing (Option)
CONNECTION OF EXTERNAL LIQUID SUPPLIES
1. Facing the rear of the machine, locate the five 3/8 inch supply hose connections found on the right-hand
side of the valve panel.
2. Drill through the five plastic holes on the valve panel for the external supply hoses as needed.
3. Remove plastic debris.
INSTALLATION
1
Flush manifold
connection (use
either left port)
19
Common
21
Pre wash
22
Main wash
23
Bleach
24
Fabric softner
Pre
wash
Main
wash Bleach
Fabric
softner
PE L1 L2 19 21 22 23 24
Single Phase
208-240V connection
Ground
connection
Common
6