Mounting 

Dimensions

Panel Mounting

Before you begin, note that the 
mounting panel cannot be more than 
5 mm thick. 

1. Make a panel cut-out measuring 

92x92 mm (3.622”x3.622”). 

2. Slide the controller into the cut-

out, ensuring that the rubber seal 
is in place. 

3. Push the 2 mounting brackets 

into their slots on the sides of the 
controller as shown in the figure 
to the right. 

4. Tighten the bracket screws 

against the panel. Hold the 
bracket securely against the unit 
while tightening the screw. 

5. When properly mounted, the 

controller is squarely situated in 
the panel cut-out as shown in the 
figure to the right. 

Summary of Contents for Vision OPLC V350-35-B1

Page 1: ... This mode enables you to View Edit operand values COM port settings RTC and screen contrast brightness settings Calibrate the touchscreen Stop initialize and reset the PLC To enter Information Mode press the i button for several seconds Programming Software Utilities The Unitronics Setup CD contains VisiLogic software and other utilities VisiLogic Easily configure hardware and write both HMI and ...

Page 2: ...eration Unitronics accepts no responsibility for actual use of this product based on these examples Please dispose of this product according to local and national standards and regulations Only qualified service personnel should open this device or carry out repairs Failure to comply with appropriate safety guidelines can cause severe injury or property damage Do not attempt to use this device wit...

Page 3: ...ller into the cut out ensuring that the rubber seal is in place 3 Push the 2 mounting brackets into their slots on the sides of the controller as shown in the figure to the right 4 Tighten the bracket screws against the panel Hold the bracket securely against the unit while tightening the screw 5 When properly mounted the controller is squarely situated in the panel cut out as shown in the figure ...

Page 4: ... kgf cm Do not use tin solder or any substance on stripped wire that might cause the wire strand to break Install at maximum distance from high voltage cables and power equipment Wiring Procedure Use crimp terminals for wiring use 26 12 AWG wire 0 13 mm 2 3 31 mm2 1 Strip the wire to a length of 7 0 5mm 0 250 0 300 inches 2 Unscrew the terminal to its widest position before inserting a wire 3 Inse...

Page 5: ...supply connect one end of a 14 AWG wire to the chassis signal connect the other end to the panel Note If possible the wire used to earth the power supply should not exceed 10 cm in length However it is recommended to earth the controller in all cases Communication Port Turn off power before making communications connections Caution Signals are related to the controller s 0V the same 0V is used by ...

Page 6: ...gnal 4 RS232 signal 5 0V reference 5 RS232 signal 6 DSR signal 6 B signal Pin 1 Standard programming cables do not provide connection points for pins 1 and 6 When a port is adapted to RS485 Pin 1 DTR is used for signal A and Pin 6 DSR signal is used for signal B RS232 to RS485 Jumper Settings The figure to the right shows the jumper factory default settings RS232 RS485 termination ON Note that in ...

Page 7: ...he back cover Changing Communication Settings 1 To access the communication jumpers hold the Power Supply PCB by its edges and steadily pull the board off 2 Locate the jumpers and then change the settings as required Jumper settings are shown on page 6 Closing the Controller 1 Gently replace the board Make certain that the pins fit correctly into their matching receptacle Do not force the board in...

Page 8: ...ot limited to any implied warranties of merchantability fitness for a particular purpose or non infringement Unitronics assumes no responsibility for errors or omissions in the information presented in this document In no event shall Unitronics be liable for any special incidental indirect or consequential damages of any kind or any damages whatsoever arising out of or in connection with the use o...