background image

UniStream

®

  

 

Unitronics 

 

 

 

Item P/N 

Accessories P/N 

End Unit 

Cable 

Base Unit 

Item 

UAG-XKxxx 

CEXP-125 / 300 

UAG-XKxxx 

UAG-XKxxx 

UAG-XKPxxx 

CEXP-125 / 300 

UAG-XKPxxx 

UAG-XKPxxx 

UAG-XKPLxxxx 

CEPL-600 / 1200 / 
1500 / 2000 / 3000 

UAG-XKPLxxxx 

UAG-XKPLxxxx 

UAG-CX-XKPxxx 

CEXP-125 / 300 

UAG-CX-XB-01 

UAG-CX-XKPxxx 

UAG-CX-XKPLxxx 

CEPL-600 / 1200 /  
1500 / 2000 / 3000 

UAG-CX-XBL-01 

UAG-CX-XKPLxxx 

   

  
 

 

Assembly Diagram: Short-range Adapters UAG-XKxxx and UAG-XKPxxx 

UniStream Modular 

UniStream PLC 

 

 

 

Bus connector 

 

 

Base Unit plug 

 

 

Clips 

 

Base Unit’s cable port 

 

Cable with RJ45 connector  

 

End Unit LED indicators  

 

DIN-rail clips, top and bottom 

 

End Unit I/O bus connector 

 

I/O Bus - Left side connector 

 

10  Model-dependent: 

 

UAG-XKxxx earth point connector 

 

UAG-XKPxxx power supply connector 

Caution 

 

  Please note that although they appear similar, the Base Units and End Units of 

Short-range and Long-range adapters are 

not

 

interchangeable

 

 

 

Summary of Contents for UniStream UAG-XK Series

Page 1: ...the Base and End units of these adapters have DIN rail clips You can Snap the base onto the DIN rail type structure on the back of UniStream Modular HMI Snap the base directly onto a UniStream PLC UAG CX The base unit of these adapters has a plug the end unit has DIN rail clips You can plug the base unit only into the I O Expansion Jack offered by the UniStream Built in series Note that the maximu...

Page 2: ... should be installed only by qualified personnel Failure to comply with appropriate safety guidelines can cause severe injury or property damage Do not attempt to use this device with parameters that exceed permissible levels Do not connect disconnect the device when power is on Environmental Considerations Ventilation 10mm 0 4 of space is required between the device top bottom edges and the enclo...

Page 3: ...AG CX XKPLxxx Assembly Diagram Short range Adapters UAG XKxxx and UAG XKPxxx UniStream Modular UniStream PLC 1 Bus connector 2 Base Unit plug 3 Clips 4 Base Unit s cable port 5 Cable with RJ45 connector 6 End Unit LED indicators 7 DIN rail clips top and bottom 8 End Unit I O bus connector 9 I O Bus Left side connector 10 Model dependent UAG XKxxx earth point connector UAG XKPxxx power supply conne...

Page 4: ...or 8 I O Bus Left side connector 9 Power supply connector Assembly Diagram Long range Adapters UAG XKPLxxxx UniStream Modular UniStream PLC 1 Bus connector 2 Base Unit plug 3 Clips 4 Base Unit s cable port blue RJ45 5 Cable with RJ45 connectors 6 End Unit LED indicators 7 DIN rail clips top and bottom 8 End Unit I O bus connector 9 I O Bus Left side connector 10 Power supply connector Caution Plea...

Page 5: ...proper precautions to prevent Electro Static Discharge ESD This kit enables you to connect a UniStream controller to a row of Uni I O modules located on a DIN rail To do this you must Connect the Base Unit to the controller Connect the End Unit to the first module in a row of Uni I O modules Link the End Unit into the Base Unit via the connecting cable If you are using a UAG XKPxxx UAG CX XKPxxx U...

Page 6: ...ing figure and plug it into the I O Expansion Jack in the rear of the device Connecting the Adapter End Unit 1 Push the End Unit onto the DIN rail until the clips located at the top and bottom of the unit have snapped onto the DIN rail 2 Install Uni I O modules to the right of the End unit Please refer to the specific Installation Guide of each Uni I O module 3 Slide the Bus Connector Lock of the ...

Page 7: ...distance from high voltage cables and power equipment Wiring Procedure Use crimp terminals for wiring use 26 12 AWG wire 0 13 mm2 3 31 mm2 1 Strip the wire to a length of 7 0 5mm 0 250 0 300 inches 2 Unscrew the terminal to its widest position before inserting a wire 3 Insert the wire completely into the terminal to ensure a proper connection 4 Tighten enough to keep the wire from pulling free Wir...

Page 8: ...t and slide it to the right Pull the End Unit s top DIN rail clip up and the bottom clip down Pull the End Unit out of its place away from the DIN rail The information in this document reflects products at the date of printing Unitronics reserves the right subject to all applicable laws at any time at its sole discretion and without notice to discontinue or change the features designs materials an...