Before You Begin 

 

Before installing the device, the installer must: 

 

Read and understand this document and related technical specifications and documents, 

located in the Technical library section of the Unitronics website. 

 

Verify the Kit Contents.  

   

  

Alert Symbols and General Restrictions 

When any of the following symbols appear, read the associated information carefully. 

Symbol 

Meaning 

Description 

 

Danger 

The identified danger causes physical and property damage. 

 

Warning 

The identified danger could cause physical and property damage. 

Caution 

Caution 

Use caution. 

 

All examples and diagrams are intended to aid understanding, and do not guarantee 

operation. Unitronics accepts no responsibility for actual use of this product based on these 

examples. 

 

Please dispose of this product according to local and national standards and regulations. 

 

This product should be installed only by qualified personnel. 

 

 

Failure to comply with appropriate safety guidelines can cause severe injury or 

property damage. 

 

Do not attempt to use this device with parameters that exceed permissible levels. 

 

Do not connect/disconnect the device when power is on. 

  

Environmental Considerations 

 

 

 

 

Ventilation: 10mm (0.4”) of space is required between the device top/bottom edges 

and the enclosure’s walls. 

 

Do not install in areas with: excessive or conductive dust, corrosive or flammable gas, 
moisture or rain, excessive heat, regular impact shocks or excessive vibration, in 

accordance with the standards and limitations given in the product’s technical 

specification sheet. 

 

Do not place in water or let water leak onto the unit.  

 

Do not allow debris to fall inside the unit during installation. 

 

Install at maximum distance from high-voltage cables and power equipment. 

 

 

Kit Contents 

Item 

Qty 

UAG-XKxxx 

UAG-XKPxxx 

UAG-CX-XKPxxx 

UAG-CX-XKPLxxxx 

UAG-XKPLxxxx

 

Local Expansion Base Unit

 

√ 

√ 

√ 

Local Expansion End Unit  

√ 

√ 

√ 

Requires connection to 
external Power Supply 

√ 

√ 

Cable 

Integrated 

Integrated 

√ 

Terminal Block 

√ 

√ 

√ 

 

 

 

Summary of Contents for UniStream UAG-XK Series

Page 1: ...the Base and End units of these adapters have DIN rail clips You can Snap the base onto the DIN rail type structure on the back of UniStream Modular HMI Snap the base directly onto a UniStream PLC UAG CX The base unit of these adapters has a plug the end unit has DIN rail clips You can plug the base unit only into the I O Expansion Jack offered by the UniStream Built in series Note that the maximu...

Page 2: ... should be installed only by qualified personnel Failure to comply with appropriate safety guidelines can cause severe injury or property damage Do not attempt to use this device with parameters that exceed permissible levels Do not connect disconnect the device when power is on Environmental Considerations Ventilation 10mm 0 4 of space is required between the device top bottom edges and the enclo...

Page 3: ...AG CX XKPLxxx Assembly Diagram Short range Adapters UAG XKxxx and UAG XKPxxx UniStream Modular UniStream PLC 1 Bus connector 2 Base Unit plug 3 Clips 4 Base Unit s cable port 5 Cable with RJ45 connector 6 End Unit LED indicators 7 DIN rail clips top and bottom 8 End Unit I O bus connector 9 I O Bus Left side connector 10 Model dependent UAG XKxxx earth point connector UAG XKPxxx power supply conne...

Page 4: ...or 8 I O Bus Left side connector 9 Power supply connector Assembly Diagram Long range Adapters UAG XKPLxxxx UniStream Modular UniStream PLC 1 Bus connector 2 Base Unit plug 3 Clips 4 Base Unit s cable port blue RJ45 5 Cable with RJ45 connectors 6 End Unit LED indicators 7 DIN rail clips top and bottom 8 End Unit I O bus connector 9 I O Bus Left side connector 10 Power supply connector Caution Plea...

Page 5: ...proper precautions to prevent Electro Static Discharge ESD This kit enables you to connect a UniStream controller to a row of Uni I O modules located on a DIN rail To do this you must Connect the Base Unit to the controller Connect the End Unit to the first module in a row of Uni I O modules Link the End Unit into the Base Unit via the connecting cable If you are using a UAG XKPxxx UAG CX XKPxxx U...

Page 6: ...ing figure and plug it into the I O Expansion Jack in the rear of the device Connecting the Adapter End Unit 1 Push the End Unit onto the DIN rail until the clips located at the top and bottom of the unit have snapped onto the DIN rail 2 Install Uni I O modules to the right of the End unit Please refer to the specific Installation Guide of each Uni I O module 3 Slide the Bus Connector Lock of the ...

Page 7: ...distance from high voltage cables and power equipment Wiring Procedure Use crimp terminals for wiring use 26 12 AWG wire 0 13 mm2 3 31 mm2 1 Strip the wire to a length of 7 0 5mm 0 250 0 300 inches 2 Unscrew the terminal to its widest position before inserting a wire 3 Insert the wire completely into the terminal to ensure a proper connection 4 Tighten enough to keep the wire from pulling free Wir...

Page 8: ...t and slide it to the right Pull the End Unit s top DIN rail clip up and the bottom clip down Pull the End Unit out of its place away from the DIN rail The information in this document reflects products at the date of printing Unitronics reserves the right subject to all applicable laws at any time at its sole discretion and without notice to discontinue or change the features designs materials an...

Reviews: