OM-202 137 Page 16
6 Minutes Welding
4 Minutes Resting
4-4.
Duty Cycle And Overheating
Duty Cycle is percentage of 10 min-
utes that unit can weld at rated load
without overheating.
If unit overheats, output stops, a
Help message is displayed (see
Section 6-3), and cooling fan runs.
Wait fifteen minutes for unit to cool.
Reduce amperage or duty cycle be-
fore welding.
NOTICE − Exceeding duty cycle
can damage unit and void warranty.
60% Duty Cycle
Overheating
0
15
A
OR
Reduce Duty Cycle
Minutes
Ref. SA-178 651
4-5.
Volt-Ampere Curves
va_curve1 4/95 − SA-178 652 / SA-178 653
Volt-ampere curves show minimum
and maximum voltage and amper-
age output capabilities of unit.
Curves of other settings fall be-
tween curves shown.
C. CC Mode
D. CV Mode
ARC CONTROL