P3 15-40
11
3 Elektrical Installation
Connection advice
This connection advice is a general information and non-obligatory.
Note:
- Connection and operating instructions
- Local regulations
- EU guideline 89/392/EWG
- VDE and TÜV regulations and Trade body guidelines
Switch on
the auxiliary voltage and the supply voltage simultaneously.
Switch off
the supply voltage after the auxiliary voltage
Input filter
see CE advice, page 15
Short conductor length to be used between the input filter and the device
Operation with 60Hz: switch S3 contact 1 in position ON
Auxiliary voltage connection
Connection
terminal X5:11, X5:12
Power supply
230V~ or 400V~ (Pls. observe the type plate)
Input current
0.1A
Phase position
regardless
Internal fuses
2.5Af
P
o
w
e
r
su
p
p
ly
X5: 11
12
18
19
20
Summary of Contents for Classic P3 400/450-15
Page 1: ...MANUAL Classic P3 1 Quadrant Thyristor Drive 15 to 40 A P3 15 40A Edition 0308 1...
Page 8: ...8 Classic P3 x x 15 40A Dimensions P3 15 25A Enable Enable ignition...
Page 9: ...P3 15 40 9 2 Mechanical Installation Dimensions P3 40A Enable Enable ignition...
Page 24: ...24 Classic P3 x x 15 40A Connection Diagram...