10
Classic P3 x/x - 15-40A
C
o
n
n
e
ct
io
n
a
d
v
ic
e
Attention:
The order of the connections to the connector numbers or screw terminals is
obligatory. All further advice is non-obligatory.
The input and output conductors may be altered or supplemented in accordance
with the electrical standards.
Note:
- Connection and operating instructions
- Local regulations
- EU guideline 89/392/EWG, 84/528/EWG, 86/663/EWG
- VDE and TÜV regulations and Trade body guidelines
- CE advice, EMC
Connection
Conductor minimal cross-section
Type current
A
15
25
40
ac power supply
mm²
1.5
2.5
4
Motor line
mm²
1.5
2.5
4
Auxiliary voltage
mm²
0.5
0.5
0.5
Summary of Contents for Classic P3 400/450-15
Page 1: ...MANUAL Classic P3 1 Quadrant Thyristor Drive 15 to 40 A P3 15 40A Edition 0308 1...
Page 8: ...8 Classic P3 x x 15 40A Dimensions P3 15 25A Enable Enable ignition...
Page 9: ...P3 15 40 9 2 Mechanical Installation Dimensions P3 40A Enable Enable ignition...