![Unitek BAMOCAR-PG-D3-700-900 Manual Download Page 31](http://html1.mh-extra.com/html/unitek/bamocar-pg-d3-700-900/bamocar-pg-d3-700-900_manual_4037715031.webp)
Electrical installation
Version: 2020 / V3
Seite: 30
BAMOCAR-PG-D3-700-900
3.8
Battery connection
Bus circuit capacitor C-ZW:
560 µF at 700 V
Discharge resistance R-ZW:
50 kΩ
Series resistor:
RV approx. 40
Ω
, 50 W
Charging current via K2:
< 20 A
Note:
Enable (RUN) only after the main
contactor K1 is activated.
The max. supply voltage (battery voltage) 740 V=
must not be exceeded at any time (not even for short intervals)!
Danger of damage!
Error message: OVERVOLTAGE
F1 = safety fuse
Programming of an output for the pre-charging:
The output Dout1 switches the relay K3 when the bus circuit voltage (DC-BUS) is greater than the
variable 1.
Warning:
The power supply connection has no protection against reverse polarity.
If the polarity of the connection is wrong, the device will be destroyed!
Type
Battery connection
Connector
cross-section
Fuse AT
Drive contactor
size
Bolt
mm²
AWG
450
M10
max. 95
4
500
Battery connecting line < 2 m. For conductor lengths from 2 to 10m more powerful.
Use an additional capacity for conductor lengths superior to 10m!
Max. connector cross-section 70mm², cable lug for M10
Summary of Contents for BAMOCAR-PG-D3-700-900
Page 23: ...Electrical installation Version 2020 V3 Seite 22 BAMOCAR PG D3 700 900 3 2 Circuit diagramm...
Page 24: ...Electrical installation Version 2020 V3 Seite 23 BAMOCAR PG D3 700 900...
Page 25: ...Electrical installation Version 2020 V3 Seite 24 BAMOCAR PG D3 700 900 3 3 Connection diagramm...