Page 22
WELD SENTRY 2
COPYING SCHEDULES AND PROGRAMS
COPY A SCHEDULE - Select this feature from the Main Menu to transfer all of the information
from one schedule to another. All associated programs and limits will be copied also. This is
recommended for any schedules developed in Schedule 0. Schedule 0 is a designed to be used as a
scratchpad and can inadvertently be replaced at any time.
USING WELD COUNTERS
WELD COUNTERS - Select this feature from the Main Menu to access the weld counter screen
shown below.
TOTAL NUMBER OF WELDS increments each time the Sentry is triggered to evaluate a weld
regardless of which schedule is selected. “Total Welds” corresponds to “Weld Count” which is
displayed on the Run state screen. To reset, enter 0 or any number up to 9999999. It may be desired
to enter an existing weld count to coordinate the Sentry with the welder. Or, it may be helpful to
reset Total Welds to zero at the same time that SPC history is reset, so that the weld counts will
match.
REJECT HI or REJECT LOW will increment once if any or all of the Programs A-E are evaluated
as a "Reject Hi" or "Reject Lo".
NOWELD will be incremented only for "No Welds" which are due to a "missing weld" (no current
flow). "No Welds" which are caused by an in-complete weld sequence are not counted by the NO
WELD counter and are not counted in the Weld Count.
ACCEPT is incremented for all welds which are not counted as Reject Hi or Low and are not
counted as No Weld.
Total Welds is equal to No Weld + Reject Hi + Reject Low.