background image

12

© 2022 United States Stove Company

OPERATION INSTRUCTIONS

PROPER FUEL

ATTENTION:

THIS APPLIANCE IS DESIGNED FOR THE USE OF 

PELLETIZED FUEL THAT MEET OR EXCEED THE 

STANDARD SET BY THE PELLET FUEL INSTITUTE 

(PFI).

Your pellet stove is designed to burn premium hardwood 

pellets that comply with the Pellet Fuels Institute (PFI) 

standard (minimum of 40 lbs density per cubic ft, 1/4” to 

5/16” diameter, length no greater than 1.5”, not less than 

8,200 BTU/lb, moisture under 8% by weight, ash under 

1% by weight, and salt under 300 parts per million). 

Pellets that are soft, contain excessive amounts of loose 

sawdust, have been, or are wet, will result in reduced 

performance. Store your pellets in a dry place. DO NOT 

store the fuel within the installation clearances of the 

unit or within the space required for refuelling and ash 

removal. Doing so could result in a house fire. Do not over 

fire or use volatile fuels or combustibles, doing so may 

cause a personal and property damage hazards.
THIS STOVE IS APPROVED FOR BURNING PELLETIZED 

WOOD FUEL ONLY ! Factory-approved pellets are those 

1/4” or 5/16” in diameter and not over 1” long. Longer or 

thicker pellets sometimes bridge the auger flights, which 

prevents proper pellet feed. Burning wood in forms other 

than pellets is not permitted. It will violate the building 

codes for which the stove has been approved and will 

void all warranties. The design incorporates automatic 

feed of the pellet fuel into the fire at a carefully prescribed 

rate. Any additional fuel introduced by hand will not 

increase heat output but may seriously impair the stoves 

performance by generating considerable smoke. Do 

not burn wet pellets. The stove’s performance depends 

heavily on the quality of your pellet fuel. Avoid pellet 

brands that display these characteristics:
•  Excess Fines – “Fines” is a term describing crushed 

pellets or loose material that looks like sawdust or sand. 

Pellets can be screened before being placed in hopper 

to remove most fines.

•  Binders – Some pellets are produced with materials to 

hold the together, or “bind” them.

•  High ash content – Poor quality pellets will often create 

smoke and dirty glass. They will create a need for more 

frequent maintenance. You will have to empty the burn 

pot plus vacuum the entire system more often. Poor 

quality pellets could damage the auger. We cannot 

accept responsibility for damage due to poor quality 

pellet.

This heater is designed to burn only PFI Premium grade 

pellets. DO NOT BURN:
1.  Garbage;
2.  Lawn clippings or yard waste;
3.  Materials containing rubber, including tires;
4.  Materials containing plastic;
5.  Waste petroleum products, paints or paint thinners, 

or asphalt products;

6.  Materials containing asbestos;
7.  Construction or demolition debris;
8.  Railroad ties or pressure-treated wood;
9.  Manure or animal remains;
10.  Salt water driftwood or other previously salt water 

saturated materials;

11.  Unseasoned wood; or
12.  Paper products, cardboard, plywood, or particleboard. 

The prohibition against burning these materials does 

not prohibit the use of fire starters made from paper, 

cardboard, saw dust, wax and similar substances 

for the purpose of starting a fire in an affected wood 

heater.

Burning these materials may result in release of toxic 

fumes or render the heater ineffective and cause smoke.

CAUTION:

•  KEEP FOREIGN OBJECTS OUT OF THE HOPPER.
•  THE MOVING PARTS OF THIS STOVE ARE 

PROPELLED BY HIGH TORQUE ELECTRIC 

MOTORS. KEEP ALL BODY PARTS AWAY FROM 

THE AUGER WHILE THE STOVE IS PLUGGED 

INTO AN ELECTRICAL OUTLET. THESE MOVING 

PARTS MAY BEGIN TO MOVE AT ANY TIME 

WHILE THE STOVE IS PLUGGED IN.

cleaners on the glass or door. Check fuel in the hopper, 

and refill if necessary.

BUILDING A FIRE

Never use a grate or other means of supporting the fuel. 

Use only the burn pot supplied with this heater. Hopper 

lid must be closed in order for the unit to feed pellets. 

During the start-up period:
•  Make sure the burn pot is free of pellets.
•  DO NOT open the viewing door.
•  DO NOT add pellets to the burn pot by hand.
NOTE: During the first few fires, your stove will emit an 

odor as the high-temperature paint cures or becomes 

seasoned to the metal. Maintaining smaller fires will 

Summary of Contents for US5517-P

Page 1: ...g or fire officials about permits restrictions and installation requirements in your area NEVER OPERATE THIS PRODUCT WHILE UNATTENDED CAUTION Please read this entire manual before you install or use y...

Page 2: ...ater meets the 2020 U S Environmental Protection Agency s crib wood emission limits for wood heaters sold after May 15 2020 Under specific EPA test conditions this heater has been shown to deliver hea...

Page 3: ...and_____________________________________________ If no Date of inspection of existing venting system ________________________________________________________________ COMMISSIONING Confirm Hearth Pad I...

Page 4: ...MUST BE PLUGGED INTO A 110 120V 60 HZ GROUNDED ELECTRICAL OUTLET DO NOT USE AN ADAPTER PLUG OR SEVER THE GROUNDING PLUG DO NOT ROUTE THE ELECTRICAL CORD UNDERNEATH IN FRONT OF OR OVER THE HEATER DO N...

Page 5: ...or non combustible surface should be large enough to cover at least the area under the product and 6 153 mm beyond the front and beyond each side of the fuel loading and ash removal openings Floor pro...

Page 6: ...ate paint or protective coating to ensure grounding Vent must be 3 or 4 inch PL Vent and must extend a minimum or 36 914 mm above the roof line of the mobile home and must be installed using a certifi...

Page 7: ...pellet vent pipe is not furnished with the unit and must be purchased separately PELLET VENT INSTALLATION The installation must include a clean out tee to enable collection of fly ash and to permit pe...

Page 8: ...d void your warranty HORIZONTAL EXHAUST VENT INSTALLATION 1 Locate your pellet stove in a location which meets the requirements of this manual but in an area where it does not interfere with the house...

Page 9: ...o get above the snowdrift line This same installation can be used if your heater is below ground level by simply adding the clean out section and vertical pipe inside until ground level is reached Wit...

Page 10: ...d and or inspected by a qualified chimney sweep before proceeding with the installation of your pellet stove 2 To the right is an example of an installation using part number 860001 3 6 transition int...

Page 11: ...at range 5 C C F Button The C F button changes the two digit display from degrees Celsius to degrees Fahrenheit D MODE M T BUTTON The Mode of the stove can be switched between manual and controlled wi...

Page 12: ...nes Binders Some pellets are produced with materials to hold the together or bind them High ash content Poor quality pellets will often create smoke and dirty glass They will create a need for more fr...

Page 13: ...CES AND A SAFETY CONCERN MAY ARISE FROM SPARKS OR FUMES ENTERING THE ROOM THE DOOR MUST BE CLOSED AND SEALED DURING OPERATION If the door is opened while the stove is in operation it must be closed wi...

Page 14: ...nge to activatetheairswitch shuttingthefuelfeedoff Thestove will shut down and show E2 on the two digit display The stove has to fully shut down before restarting INTERIOR CHAMBERS Burn Pot Periodical...

Page 15: ...of chimney in use A qualified chimney sweep can perform this service It is also recommended that before each heating season the entire system be professionally inspected cleaned and if necessary repai...

Page 16: ...glass from the door frame 4 Replace the glass and gasket making sure the gasket runs the full perimeter of the glass edge 5 Re install the retainer and eight nuts and rope gasket using high temperatu...

Page 17: ...ion of this manual Close the slide about 1 4 after your stove cools down Restart your stove If your display shows E1 again close the slide another 1 4 and restart The convection blower is overheating...

Page 18: ...ombustion blower failure With the stove on check to see if the combustion blower is running If it is not you will need to check for power going to the combustion blower It should be a full current If...

Page 19: ...move the two bolts that hold the auger bracket to the auger tube The auger bracket will now be able to be removed form the auger tube Remove the two bolts on the side of the auger tube to remove the l...

Page 20: ...pper is open When operating the unit be sure the hopper lid is closed so that the hopper safety switch will activate Check the wires leading from the hopper safety switch to the control panel and auge...

Page 21: ...The Home Possible Causes Possible Remedies Unplug stove first when possible There is a leak in the vent pipe system Inspect all vent pipe connections Make sure they are sealed with RTV silicone that...

Page 22: ...NOTE NUMBERS 4 6 16 ARE NOT YET SHOWN Key Part Description Qty 1 88174 1 8 X 1 Window Gasket W Adhesive 7 28 ft 2 893159 Clear Glass 1 3 88324 1 Rope Gasket 5 17 ft 4 80780 IR Remote 1 5 893629 Burnpo...

Page 23: ...ordered Before contacting customer service write down the model number and the serial number of this unit That information can be found on the certification label attached to the back of the unit Oth...

Page 24: ..._____ Engineer Name _____________________________________ License No _________________________________________ Company ___________________________________________ Telephone No ________________________...

Page 25: ...2022 United States Stove Company 25 NOTES...

Page 26: ...26 2022 United States Stove Company NOTES...

Page 27: ...2022 United States Stove Company 27 NOTES...

Page 28: ...____________________ Service de 07 Date ______________________ Nom de l ing nieur _________________________________ N de licence ______________________________________ Compagnie ______________________...

Page 29: ...areil Lors de la commande de pi ces de rechange les informations contenues dans ce manuel vous aideront vous assurer que les bons articles sont command s Avant de contacter le service client notez le...

Page 30: ...sif 7 28 pi 2 893159 Verre propre 1 3 88324 Joint de corde 1 po 5 17 pi 4 80780 T l commande IR 1 5 69762 Assemblage du pot de combustion 1 6 80491 Micro interrupteur 1 7 80518 Assemblage du clavier 1...

Page 31: ...nt deux fois par seconde Cela indique que le po le fonctionne normalement et qu une condition de temp rature excessive existe provoquant l arr t du combustible Indicateur de r glage du niveau de chale...

Page 32: ...st me vis sans fin est bloqu ou il y a une vo te de combustible dans la tr mie qui emp che le combustible de s couler dans le syst me d approvisionnement vis sans fin PROBL ME CAUSE L allumeur automat...

Page 33: ...propri taire sont sp cifiques votre appareil Lors de la commande de pi ces de rechange les informations contenues dans ce manuel vous aideront vous assurer que les bons articles sont command s Avant...

Page 34: ...verre N UTILISEZ PAS de nettoyants abrasifs N effectuez PAS le nettoyage lorsque la vitre est CHAUDE N essayez pas de faire fonctionner l appareil avec du verre bris Le verre de remplacement peut tre...

Page 35: ...p cialement con ue pour le type de chemin e utilis Un ramoneur qualifi peut fournir ce service Il est galement conseill d inspecter de nettoyer et si n cessaire de r parer la totalit du syst me avant...

Page 36: ...ent le pot de combustion et la zone l int rieur du bo tier du pot de combustion En particulier il est conseill de nettoyer les trous du pot de combustion pour liminer toute accumulation qui pourrait e...

Page 37: ...S CIRCONSTANCES ET UN PROBL ME DE S CURIT PEUT PROVOQUER DES TINCELLES OU DES FUM ES ENTRANT DANS LA PI CE LA PORTE DOIT TRE FERM E ET SCELL E PENDANT LE FONCTIONNEMENT Si la porte est ouverte pendant...

Page 38: ...sont mouill s r duiront les performances Rangez vos pellets dans un endroit sec NE stockez PAS le carburant dans les d gagements d installation de l appareil ou dans l espace requis pour faire le ple...

Page 39: ...faire en sorte que le po le se programme entre le r glage pr s lectionn de la plage de chaleur d sir e 1 5 et le r glage de la plage de chaleur minimale de 1 Le T Stat n allumera ni ne teindra le po...

Page 40: ...pour r gler la vitesse du ventilateur Quand le syst me de chauffage est en mode manuel le thermostat en option ne contr lera pas correctement l unit Lorsque vous ajustez le r glage du ventilateur de t...

Page 41: ...ent sur le diagramme en barres passant du niveau 1 au niveau 5 de chauffage C Touche C F La touche C F fait passer l affichage deux chiffres des degr s Celsius aux degr s Fahrenheit et vice versa D TO...

Page 42: ...illustrations ci dessous ne sont que des exemples Veuillez confirmer tous les codes du b timent locaux ou ragulations ayant comp tence avant de demander un installateur qualifi de proc der cette insta...

Page 43: ...L installation travers le mur est l installation la moins ch re et la plus simple Ne jamais mettre fin l vent de fin sous un pont dans une alc ve sous une fen tre ou entre deux fen tres 90 Elbow Cap d...

Page 44: ...ure 4 Localisez le centre du tuyau d chappement de votre unit Ce point devrait ensuite tre tendu la paroi int rieure de votre maison Une fois que vous avez localis le point central sur la paroi int ri...

Page 45: ...coude ou t r duit le potentiel de tirage de 30 50 Tous les joints du syst me de ventilation doivent tre fix s par au moins 3 vis et tous les joints doivent tre scell s avec du mastic silicone Hi Temp...

Page 46: ...obligatoire pour l installation d une maison mobile Consultez la section Alimentation en air ext rieur et votre revendeur pour l achat V rifiez aupr s de vos responsables locaux du b timent car d aut...

Page 47: ...des cendres La protection du plancher doit s tendre sous et 2 51 mm de chaque c t du t de chemin e pour une installation verticale int rieure Les installations canadiennes n cessitent un minimum de 18...

Page 48: ...UPEZ PAS LA FICHE DE TERRE N ACHEMINEZ PAS LE CORDON LECTRIQUE SOUS DEVANT OU SUR LE PO LE NE FAITES PAS COURIR LE CORDON LECTRIQUE DANS LES ZONES DE PASSAGE ET NE LE COINCEZ PAS SOUS LES MEUBLES ATTE...

Page 49: ...n date d inspection du syst me de ventilation existant ___________________________________________________________________ MISE EN SERVICE Confirmer l installation du tapis de foyer conform ment aux i...

Page 50: ...bs hr Taille de Pellet peut effectuer le taux r el d alimentation en carburant et de br ler fois Taux d alimentation en carburant peut varier par autant que 20 Utiliser PFI carburant list pour de meil...

Page 51: ...ictions et les exigences d installation dans votre r gion NE JAMAIS UTILISER CE PRODUIT SANS SURVEILLANCE MISE EN GARDE Veuillez lire l int gralit de ce manuel avant d installer ou d utiliser votre no...

Reviews: