background image

6

© 2021 United States Stove Company

CLEARANCES TO COMBUSTIBLES

WARNING: RISK OF FIRE

OBSERVE THE MINIMUM CLEARANCES TO 

COMBUSTIBLES STATED IN THIS MANUAL AND 

ON THE LABELS ATTACHED TO THE APPLIANCE. 

DO NOT STORE WOOD, ANY TYPE OF FLAMMABLE 

VAPORS OR LIQUIDS, PLACE FURNITURE, RUGS, 

CARPET, CLOTHING OR OTHER COMBUSTIBLE 

OBJECTS WITHIN THE CLEARANCE AREA.

Fireplace Opening Dimensions

A Minimum Width

29” 737 mm

B Minimum Height

23” 585 mm

C Minimum Depth

14” 356 mm

 Clearance to Combustibles

D Min. Distance to Sidewall

9”

229 mm

E Min. Distance to Top Trim

14” 356 mm

F Min. Distance to Mantle

19” 483 mm

G Min. Distance to Side Trim

9”

229 mm

H Min. Floor Protector Front

17”

432 mm

I

Min. Floor 

Protector 

Side

USA

6”

153 mm 

Canada

8”

204 mm

OUTSIDE COMBUSTION AIR

WARNING:

ALWAYS CONNECT THIS APPLIANCE TO A 

CHIMNEY THAT VENTS TO THE OUTSIDE. NEVER 

VENT INTO ANOTHER ROOM, CRAWL SPACE, 

ATTIC, OR INSIDE A BUILDING. DO NOT CONNECT 

THIS UNIT TO A CHIMNEY FLUE SERVING 

ANOTHER APPLIANCE.

Your appliance itself does not create draft. Draft is 

provided by the chimney. To help provide the required 

draft there is a fresh air kit (4FAK) available for purchase 

from your local stove dealer. When installed properly 

the 4FAK kit is designed to provide the draft needed for 

proper operation. To achieve proper draft your chimney 

must meet the three minimum height requirements (see 

masonry chimney section of this manual). A minimum 

draft of 0.05 w.c. (measured in water column) is required 

for proper drafting to prevent back puffing, smoke spillage, 

and to maximize performance. Gauges to measure draft 

are readily available at stove stores and are economical 

to rent or purchase. Factors such as wind, barometric 

pressure, trees, terrain and chimney temperature can 

have an adverse effect on the draft. The manufacturer 

cannot be held responsible for external factors leading 

to less than optimal drafting. Should you have a problem 

with inadequate draft, you should contact a licensed 

heating and cooling contractor for assistance in solving 

the problem.

FIREPLACE CONDITION AND ZERO 

CLEARANCE REQUIREMENTS

A masonry fireplace must meet minimum code 

requirements, National Fire Protection Association, 

(NFPA) 211, or the equivalent for a safe installation. 

Contact a professional, licensed installer, your local 

building inspector or the local fire authority for the 

requirements in your area. Your insurance company 

should be able to recommend a qualified inspector.
Inspections should include the following:
1.  Condition of the fireplace and chimney. A masonry 

fireplace and chimney MUST be inspected prior to 

installation of this appliance. They must be free from 

cracks, loose mortar, creosote deposits, blockage 

or other evidence of deterioration. If found, these 

items MUST be repaired prior to installation. DO NOT 

REMOVE BRICKS or MORTAR from existing fireplace 

when installing this unit.

2.  Chimney Size. Minimum chimney size is 6” (153 

mm) diameter. Maintain a 15 ft. minimum overall 

INSTALLATION

Summary of Contents for US1800E

Page 1: ...ions and installation requirements in your area NEVER OPERATE THIS PRODUCT WHILE UNATTENDED CAUTION Please read this entire manual before you install or use your new room heater Failure to follow inst...

Page 2: ...operation at high burn rate burning cordwood 27 1 8 691 mm 26 1 2 673 mm 13 1 4 337 mm 6 1 155 mm 21 3 4 553 mm 22 3 8 568 mm 15 1 2 394 mm 4 11 16 119 mm CAUTIONS HOT WHILE IN OPERATION KEEP CHILDRE...

Page 3: ..._________________________________________ If no Date of inspection of the existing chimney system ___________________________________________________________ COMMISSIONING Confirm Hearth Pad Installat...

Page 4: ...the top of the appliance The surround assembly is held in place with two springs at the top of either corner of the appliance SPRING SURROUND Slots in surround slide of firebox top Figure 6 Surround I...

Page 5: ...IED INSTALLER TO ENSURE A CORRECT AND SAFE INSTALLATION NEVER USE TEMPORARY OR MAKESHIFT COMPROMISES DURING THE INSTALLATION WARNING PROVIDE ADEQUATE COMBUSTION AIR TO THE ROOM WHERE THE APPLIANCE IS...

Page 6: ...ion of this manual A minimum draft of 0 05 w c measured in water column is required forproperdraftingtopreventbackpuffing smokespillage and to maximize performance Gauges to measure draft are readily...

Page 7: ...is a building code requirement Inadequate air supply will cause poor combustion inefficient operation creosote buildup back drafting and smoke puffing into the living areas If any of the following con...

Page 8: ...plate to a visible location in the fireplace After choosing a visible location in the fireplace permanently attach the warning plate by screwing or nailing it into place Note Use the holes in the labe...

Page 9: ...he chimney must meet all minimum height requirements 4 Never use a chimney to ventilate a cellar or basement Contact your local building authority for approved methods of installation and any necessar...

Page 10: ...HAZARDS FROM HIGH SURFACE TEMPERATURES NEVER LEAVE SMALL CHILDREN UNSUPERVISED WHEN THEYAREINTHESAMEROOMASTHEAPPLIANCE DURING OPERATION TO PREVENT BURNS ALWAYS WEAR PROTECTIVE CLOTHING LEATHER HEARTH...

Page 11: ...itions These problems can be ignition problems creosote build up causing chimney fires low energy yield blackened windows incomplete log combustion Do not burn manufactured logs made of wax impregnate...

Page 12: ...inutes each The third fire should be at a temperature of approximately 500 F for 20 minutes Provide adequate cross ventilation to clear any smoke or odor caused by initial firings Notice Use solid woo...

Page 13: ...can be an effective method of determining how efficiently the combustion process is taking place in the given settings Visible smoke consists of unburned fuel and moisture leaving your stove Learn to...

Page 14: ...dry wood This allows clean burns and higher chimney temperatures therefore less creosote deposit Leave the air control fully open for about 5 min every time you reload the stove to bring it back to p...

Page 15: ...it When replacing the glass you should change the glass gasket to make sure you keep it sealed Never wash the glass with a product that may scratch Use a specialized product available in the stores w...

Page 16: ...to your unit When ordering replacement parts the information in this manual will help to ensure the correct items are ordered Before contacting customer service write down the model number and the se...

Page 17: ...13 83913 Extension Spring 2 14 26269 Top Surround 1 15 26270 Side Surround 2 16 891992 1 Surround Trim R 1 17 891992 2 Surround Trim L 1 18 891992 3 Surround Top Trim L 1 19 891992 4 Surround Top Trim...

Page 18: ...1 5 891989 1 Firebrick 3 33 x 9 8 6 86963 Secondary Tube 3 7 88158 Ceramic Fiber Board Front 1 8 88159 Ceramic Fiber Board Rear 1 9 88160 Blanket Insulation 1 3 2 5 4 1 6 8 9 7 REPAIR PARTS To order...

Page 19: ...______ Engineer Name _____________________________________ License No _________________________________________ Company ___________________________________________ Telephone No _______________________...

Page 20: ...20 2021 United States Stove Company NOTES...

Page 21: ...ce de 07 Date ______________________ Nom de l ing nieur _________________________________ N de licence ______________________________________ Compagnie ________________________________________ N de t...

Page 22: ...3 33 x 9 8 6 86963 Tube secondaire 3 7 88158 Panneau en fibre de c ramique avant 1 8 88159 Panneau en fibre de c ramique arri re 1 9 88160 Isolation de couverture 1 3 2 5 4 1 6 8 9 7 Pour commander d...

Page 23: ...1 5 893261 Glissi re d amortisseur 1 6 29301 Accolade coulissante 2 7 893261 Manche en bois 1 8 29300 Couverture 1 9 29298 Amortisseur 1 10 611007 Cabinet gauche 1 11 892294 Axe De Charni re 2 12 4057...

Page 24: ...informations contenues dans ce manuel vous aideront vous assurer que les bons articles sont command s Avant de contacter le service client notez le num ro de mod le et le num ro de s rie de cet appare...

Page 25: ...remplacez la pi ce endommag e par une nouvelle Effectuez la proc dure l envers apr s l avoir remplac Lors du remplacement de la vitre vous devez changer le joint en verre pour vous assurer de le garde...

Page 26: ...TE Br lez toujours du bois sec Cela permet des br lures propres et des temp ratures de chemin e plus lev es donc moins de d p t de cr osote Laissez le contr le d air compl tement ouvert pendant enviro...

Page 27: ...frir un m lange pr cis d air secondaire et assurer une plus grande efficacit Tout dommage ou d t rioration de ces conduits peuvent r duire l efficacit de la combustion Les conduits d air sont maintenu...

Page 28: ...charbon tabli chargez l unit avec 14 15 lb de bois de corde et fermez imm diatement la porte Laissez la commande d air compl tement ouverte en position HI pendant 15 minutes Apr s 15 minutes tournez l...

Page 29: ...IMINER LA FUM E ET L ODEUR SI L APPAREIL EST SURCHAUFF LA PEINTURE SE D COLORE LORS DE L INSTALLATION DE VOTRE APPAREIL PRENEZ SOIN DE LA MANIPULATION NETTOYER AVEC DU SAVON ET DE L EAU LORSQUE L APPA...

Page 30: ...tre po le bois Le bois doit avoir s ch pendant 9 15 mois de sorte que la teneur en humidit en poids soit r duite en dessous de 20 du poids de la b che Il est tr s important de garder l esprit que m me...

Page 31: ...MAISON NE CONSERVEZ PAS LE BOIS SUR UN PROTECTEUR DE PLANCHER SOUS LES TUYAUX DE PO LE OU N IMPORTE O DANS LES D GAGEMENTS DES SURFACES COMBUSTIBLES SP CIFI ES POUR CET APPAREIL NE JAMAIS FAIRE FONCT...

Page 32: ...our ventiler une cave ou un sous sol Contactez les autorit s locales pour d finir les m thodes approuv es d installation et d terminer la n cessit d obtenir un permis et ou de r aliser une inspection...

Page 33: ...ble dans le foyer Apr s avoir choisi un emplacement visible dans le foyer fixez d finitivement la plaque d avertissement en la vissant ou en la clouant Remarque Utilisez les trous de l tiquette pour m...

Page 34: ...ote un refoulement d air et de fum e dans les pi ces vivre Si n importe laquelle des conditions suivantes est incontestablement pr sente une alimentation d air doit tre install e a L appareil actuel d...

Page 35: ...les d versements de fum e et pour maximiser les performances Des jauges pour mesurer le tirage sont facilement disponibles dans les magasins de po les et sont conomiques louer ou acheter Des facteurs...

Page 36: ...NE CHEMIN E D APPAREIL DE CHAUFFAGE DE B TIMENT HOMOLOGU E UL 103 HT U UTILISEZ UNE CHEMIN E DE 6 DE DIAM TRE ASSEZ LEV E POUR CR ER UN TIRAGE SUFFISANT ATTENTION FOURNISSEZ DE L AIR DE COMBUSTION AD...

Page 37: ...il SPRING SURROUND Slots in surround slide of firebox top Figure 6 Surround Installation Installation de l habillage RESSORT HABILLAGE Entailles dans l habillage glissent sur le dessus de l insert 6 L...

Page 38: ...ion du syst me de chemin e existant ____________________________________________________________________ MISE EN SERVICE Confirmer l installation du tapis de foyer conform ment aux instructions d inst...

Page 39: ...8 cm 27 1 8 691 mm 26 1 2 673 mm 13 1 4 337 mm 6 1 155 mm 21 3 4 553 mm 22 3 8 568 mm 15 1 2 394 mm 4 11 16 119 mm AVERTISSEMENTS CHAUD DURANT LE FONCTIONNEMENT MAINTENEZ LES ENFANTS LES V TEMENTS ET...

Page 40: ...gion NE JAMAIS UTILISER CE PRODUIT SANS SURVEILLANCE MISE EN GARDE Veuillez lire l int gralit de ce manuel avant d installer ou d utiliser votre nouveau radiateur Le non respect des instructions peut...