background image

853614---3505i

R

U.S. Environmental Protection Agency

Certified  to  comply  with  2020  particulate 

emission  standards  for  single  burn  rate 

heaters. This single burn rate wood heater is 

not approved for use with a flue damper.

United States Stove Company

227 Industrial Park Road

South Pittsburg, TN 37380

MODEL: US1269E Log Wood

CALIFORNIA PROPOSITION 65 WARNING:

This product can expose you to chemicals including carbon monoxide, which 
is known to the State of California to cause cancer, birth defects and/or other 

reproductive harm. For more information, go to www.P65warnings.ca.gov

SAFETY NOTICE:

If this heater is not properly installed, a house 

fire  may  result.  For  your  safety,  follow  the 

installation instructions. Never use make-shift 

compromises  during  the  installation  of  this 

heater. Contact local building or fire officials 

about  permits,  restrictions  and  installation 

requirements in your area.

CAUTION!

Please  read  this  entire  manual  before  you 

install  or  use  your  new  room  heater.  Failure 

to  follow  instructions  may  result  in  property 

damage,  bodily  injury,  or  even  death. 

Improper  Installation  Could  Void  Your 

Warranty!

DO  NOT  USE  THIS  HEATER  IN  A  MOBILE  HOME. 

SAVE  THESE  INSTRUCTIONS  THIS  MANUAL  WILL 

HELP  YOU  TO  OBTAIN  EFFICIENT,  DEPENDABLE 

SERVICE  FROM  THE  HEATER,  AND  ENABLE  YOU 

TO ORDER REPAIR PARTS CORRECTLY. KEEP IN A 

SAFE PLACE FOR FUTURE REFERENCE.

Certified to UL 1482-2011 (R2015) 

and ULC-S627-00 (R2016)

Report Number: F19-526

Summary of Contents for US1269E

Page 1: ...roperly installed a house fire may result For your safety follow the installation instructions Never use make shift compromises during the installation of this heater Contact local building or fire of...

Page 2: ...his heater meets the 2020 U S Environmental Protection Agency s crib wood emission limits for woodheaters sold after May 15 2020 Under specific EPA test conditions burning Douglas Fir dimensional lumb...

Page 3: ...Using Coal and Wood Stoves Safely NFPA No HS 10 1978 The address of the NFPA is Batterymarch Park MA 02269 For more information on a Canadian Installation obtainacopyofCAN CSA B365 M91Installation Cod...

Page 4: ...fety Glasses Hearth Gloves Pencil 6 Folding Ruler or Tape Measure Tin Snips Drill 1 8 dia Drill Bit Adjustable Wrench 2 philips screw driver Chimney Connector 1 2 Sheet Metal Screws Chimney Furnace Ce...

Page 5: ...he front legs to the hearth with two 2 1 4 20 x 1 3 4 screws two 2 washers and two 2 1 4 20 jam nuts NOTE Only one leg is equipped with a handle bracket This bracketed leg is designed to be installed...

Page 6: ...ry chimney properly lined or a UL ULC Listed chimney Ensure that the fixed flue baffle that is provided is installed in the flue collar This baffle is intended to be in a fixed location for optimal co...

Page 7: ...ior portion of the chimney RULES FOR CONNECTOR PIPE INSTALLATION 1 The crimped end of the pipe must be installed toward the heater The pipe should slide into the flue collar The pipe should be firmly...

Page 8: ...om combustible materials by a minimum of 6 glass fiber insulation The opening in the combustible wall shall be covered and the thimble supported with sheet steel supports which are at least 24 gauge 0...

Page 9: ...ctions packaged with it to provide a safe method of passing chimney connector through a combustible wall for a connection to a masonry chimney CONNECTION OF CHIMNEY CONNECTOR TO A MASONRY CHIMNEY WHEN...

Page 10: ...garbage 2 Lawn clippings or yard waste 3 Materials containing rubber including tires 4 Materials containing plastic 5 Waste petroleum products paints or paint thinners or asphalt products 6 Materials...

Page 11: ...d is damp If the wood hisses and water or vapor escapes at the ends of the piece the wood is soaked or freshly cut Do not use this wood in the stove Large amounts of creosote could be deposited in the...

Page 12: ...urn rates are not always the best heating burn rates after a good fire is established a lower burn rate may be a better option for efficient heating A lower burn rate slows the flow of usable heat out...

Page 13: ...the heated flue liner ASH REMOVAL AND DISPOSAL Whenever ashes get 3 to 4 inches deep in the firebox or ash pan and when the fire has burned down and cooled remove excess ashes Leave an ash bed approxi...

Page 14: ...r having completed this operation AIR TUBES The air tubes assembled in this unit are designed to provide an accurate mix of secondary air to ensure the highest efficiency Any damage or deterioration o...

Page 15: ...n Top 1 3 88033 3 8 Rope Joint Top 1 4 88329 Baffle Board 1 5 893217 Tube Weldment 1 6 86961 1 Side Secondary Tube 1 7 86962 2 Side Secondary Tube 1 8 40299 Main Back 1 9 40892 Firebox Side 2 10 40897...

Page 16: ...16 Notes...

Page 17: ...7 Date _____________________ Engineer Name ________________________________ License No ____________________________________ Company _____________________________________ Telephone No _________________...

Page 18: ...EFFICACE ET FIABLE DE L APPAREIL DE CHAUFFAGE ET VOUS PERMETTRA DE COMMANDER CORRECTEMENT DES PI CES DE RECHANGE VEUILLEZ CONSERVER CE GUIDE DANS UN ENDROIT S R DES FINS DE R F RENCE LORSQUE VOUS NOUS...

Page 19: ...____________________________ Service de 07 Date _____________________ Nom de l ing nieur ____________________________ N de licence _________________________________ Compagnie _________________________...

Page 20: ...d flecteur 1 5 893217 tube soud 1 6 86961 Tube secondaire 1 c t 1 7 86962 Tube secondaire 2 c t s 1 8 40299 dos principal 1 9 40892 c t bo te feu 2 10 40897 fond principal 1 11 40817 jambe 4 12 89975...

Page 21: ...SECONDAIRES Les conduits d air secondaires doivent tre nettoy s avec une brosse m tallique Si des d bris demeurent dans les trous frappez l g rement avec un b ton de bois pour les d loger CONDUITS D...

Page 22: ...ions de fum e et du monoxyde de carbone CO Le CO est un gaz poison lorsque l exposition se fait des concentrations lev es pour une p riode de temps prolong e Bien que les syst mes de combustion modern...

Page 23: ...la chemin e et il consume galement moins de bois CONSEILS DE FONCTIONNEMENT POUR UNE COMBUSTION DE QUALIT EFFICACE ET PROPRE Utilisez de plus petits morceaux de bois pendant l allumage et un taux de...

Page 24: ...de cr osote pourraient se d poser dans votre chemin e cr ant les conditions pour un potentiel feu de chemin e AVERTISSEMENT DE SABOTAGE Ce chauffage au bois a un taux de combustion minimum r gl la fab...

Page 25: ...ction de br lage de ces mat riaux n interdit pas l utilisation d allume feu compos s de papier carton sciure de bois cire et substances similaires aux fins de d marrer le feu dans un chauffage au bois...

Page 26: ...dans la maison ou une accumulation excessive d eau ou de cr osote dans la chemin e est un avertissement que la chemin e ne fonctionne pas correctement Corrigez le probl me avant d utiliser le chauffa...

Page 27: ...A CHEMIN E ET LA MA ONNERIE LE SUPPORTS DE T LE D ACIER ET LES MAT RIAUX COMBUSTIBLES DE 5 CM 2 PO LONGUEUR DE CHEMIN E GALIT AVEC LE CONDUIT DE FUM E INT RIEUR CIMENT R FRACTAIRE NON SOLUBLE CHEMIN E...

Page 28: ...s 24 0 024 po d paisseur Les supports de t le d acier doivent tre solidement fix s aux surfaces murales sur tous les c t s et tre d une taille suffisante pour s ajuster et maintenir la section de chem...

Page 29: ...eut provoquer un retour de souffle dans la pi ce et un colmatage de la chemin e ou du catalyseur le cas ch ant Un tirage inad quat entra nera une fuite de fum e dans la pi ce par les joints de l appar...

Page 30: ...chemin e commence dans le plafond vous aurez besoin d une longueur de tuyau de 15 cm 6 po pour l atteindre Le haut de la chemin e doit tre au moins 91 cm 3 pi au dessus du toit et d passer d au moins...

Page 31: ...2 Encore une fois v rifiez les illustrations suivantes et assurez vous d avoir les d gagements montr s du chauffage et du tuyau de raccordement par rapport aux surfaces combustibles Si vous avez de la...

Page 32: ...20 6 Fixez les pieds avant au foyer avec deux 2 vis 1 4 20 x 1 3 4 deux 2 rondelles et deux 2 contre crous 1 4 20 REMARQUE Un seul pied est quip d un support de poign e Ce pied support est con u pour...

Page 33: ...assemblage AVIS United States Stove Company n accorde aucune garantie implicite ou d clar e pour l installation ou l entretien de votre po le bois et n assume aucune responsabilit quant tous dommages...

Page 34: ...artir de l ext rieur de la maison dans la pi ce o le chauffage est situ Si la prise n est pas dans la m me pi ce l air doit avoir un acc s libre dans la pi ce 8 Pour viter les blessures ne laissez per...

Page 35: ...tuyau de raccordement 15 cm 6 po Type de tuyau de raccordement Mur simple standard Noir ou acier bleui 650 C 2100 F Hauteur minimum de la chemin e 3 7 m 12 pi Longueur maximum de b che 483 mm 19 po l...

Page 36: ...les appareils de chauffage combustion simple Ce po le bois combustion unique n est pas approuv pour utilisation avec un registre de combustion United States Stove Company 227 Industrial Park Road Sou...

Reviews: