-4-
WARNING: Never leave the heater unattended while operating.
Disconnect the heater from its power source when not in use.
-5-
WARNING: Never leave the heater unattended while operating.
Disconnect the heater from its power source when not in use.
SAFETY PRECAUTIONS
1.
Check the heater thoroughly for damage. DO NOT operate a damaged heater.
2.
DO NOT modify the heater or operate a heater which has been modified from its original condition.
3.
DO NOT light or operate heater unless the shells are fully extended and locked into position.
4.
Use only propane gas.
5.
Use only VAPOR WITHDRAWAL propane supply. If there is any question about vapor withdrawal, ask your propane dealer.
6.
Mount the propane cylinders vertically (shutoff valve up). Secure them from falling or being knocked over and protect them
from damage.
7.
Locate propane containers at least (USA) 7 ft. (2.13m) from the heater and do not direct exhaust toward containers.
8.
IMPORTANT Use only the hose and regulator assembly provided with the heater. Match the color stripe on the hang tag
attached to the hose assembly with the color on the label located near the propane inlet fitting on the heater. Inspect hose
assembly before each use of the heater. If there is excessive abrasion or wear, or hose is cut, replace with hose assembly listed
on parts list before using heater.
9.
For indoor use only. Area must be well ventilated. (Also see “Operating Precautions”).
10.
If at any time gas odor is detected, IMMEDIATELY DISCONTINUE operation until the source of gas has been located and
corrected.
11.
Install the heater such that it is not directly exposed to water spray, rain and/or dripping water.
12.
Maintain minimum clearance from normal combustible material (like paper).
13.
Due to the high surface and exhaust temperatures, adults and children must observe clearances to avoid burns or clothing
ignition.
14.
Operate only on a stable, level surface.
15.
Do not use with duct work. Do not restrict inlet or exit.
16.
Do not move, handle or service while hot or burning.
17.
Use only in accordance with local codes or, in the absence of local codes, with the Standard for the Storage and Handling of
Liquefied Petroleum Gases ANSI/ NFPA 58 and CSA B149.1, Natural Gas and Propane Installation Code.
MINIMUM CLEARANCE
From normal combustible material
Clearance
From sides
4 ft
From top
6 ft
Locate 10' from canvas or plastic tarpaulins or similar
coverings and secure them to prevent flapping or
movement due to wind action.
GENERAL INFORMATION