WARNING: Never leave the heater unattended while operating. 

Disconnect the heater from its power source when not in use.

-3-

WARNING: Never leave the heater unattended while operating. 

Disconnect the heater from its power source when not in use.

GENERAL SAFETY INFORMATION

 GENERAL HAZARD WARNING:

FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUCTIONS PROVIDED WITH THIS HEATER, CAN RESULT IN 

DEATH, SERIOUS BODILY INJURY AND PROPERTY LOSS OR DAMAGE FROM HAZARDS OF FIRE, EXPLOSION, BURN, 

ASPHYXIATION, CARBON MONOXIDE POISONING, AND/OR ELECTRICAL SHOCK.

ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD USE OR SERVICE THIS HEATER. 
IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS AN INSTRUCTIONS MANUAL, LABELS, ETC. CONTACT 

THE MANUFACTURER.

 WARNING:

THE STATE OF CALIFORNIA REQUIRES THE FOLLOWING WARNING

COMBUSTION BY-PRODUCTS PRODUCED WHEN USING THIS PRODUCT CONTAIN CARBON MONOXIDE, A CHEMICAL 

KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER AND BIRTH DEFECTS (OR OTHER REPRODUCTIVE HARM). 

THIS PRODUCT CONTAINS CHEMICALS KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER AND BIRTH 

DEFECTS OR OTHER REPRODUCTIVE HARM.

 WARNING:

FIRE, BURN, INHALATION, AND EXPLOSION HAZARD. KEEP SOLID COMBUSTIBLES, SUCH AS BUILDING MATERIALS, 

PAPER OR CARDBOARD, A SAFE DISTANCE AWAY FROM THE HEATER AS RECOMMENDED BY THE INSTRUCTIONS 

NEVER USE THE HEATER IN SPACES WHICH DO OR MAY CONTAIN VOLATILE OR AIRBORNE COMBUSTIBLES, OR 

PRODUCTS SUCH AS GASOLINE, SOLVENTS, PAINT THINNER, DUST PARTICLES OR UNKNOWN CHEMICALS.

 WARNING:

NOT FOR HOME OR RECREATIONAL VEHICLE USE.

 WARNING:

YOUR SAFETY IS IMPORTANT TO YOU AND TO OTHERS, SO PLEASE READ THESE INSTRUCTIONS BEFORE YOU OPERATE 

THIS HEATER.

Summary of Contents for HEATFAST HF200C

Page 1: ...exactly a fire or explosion may result causing property damage personal injury or loss of life READ INSTRUCTIONS CAREFULLY Read and follow all instructions Place instructions in a safe place for futur...

Page 2: ...ES THE FOLLOWING WARNING COMBUSTION BY PRODUCTS PRODUCED WHEN USING THIS PRODUCT CONTAIN CARBON MONOXIDE A CHEMICAL KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER AND BIRTH DEFECTS OR OTHER REPRODUC...

Page 3: ...all connection instructions herein Also ask your propane dealer for advice on the propane application and supply installation and ask him to check it if there are any questions This heater was design...

Page 4: ...eater If there is excessive abrasion or wear or hose is cut replace with hose assembly listed on parts list before using heater 9 For indoor use only Area must be well ventilated Also see Operating Pr...

Page 5: ...INCLUDE HEADACHES DIZZINESS AND DIFFICULTY IN BREATHING WARNING AIR QUALITY HAZARD USE OF DIRECT FIRED HEATERS IN THE CONSTRUCTION ENVIRONMENT CAN RESULT IN EXPOSURE TO LEVELS OF CO CO2 AND NO2 CONSI...

Page 6: ...supply valve located at the meter if you use natural gas Propane LP gas is heavier than air and may settle in low areas When you have reason to suspect a propane leak keep out of all low areas Use you...

Page 7: ...ne LP gas fuel system A periodic sniff test around the heater or at the heater s joints i e hose connections etc is a good safety practice under any conditions If you smell even a small amount of gas...

Page 8: ...knob counterclockwise until the piezo igniter clicks Continue to rotate and activate the igniter until the burner lights 5 Once the burner lights hold the knob in on the low position for 30 seconds T...

Page 9: ...this regard use only the hose regulator and cylinder connection fitting called a POL fitting supplied with the heater IMPORTANT Match the color stripe on the hang tag attached to the hose assembly wit...

Page 10: ...r Orifice Assembly 1 3 893994 Burner Cone Assembly 1 4 893998 Combustion Chamber Ring 1 5 893991 Control Knob 1 6 81380 Valve and Gas Assembly 1 7 81376 Hose Regulator Assembly 10 1 1 2 3 4 5 7 6 IN O...

Page 11: ...sembly 1 3 893997 Burner Cone 1 4 893998 Combustion Chamber Ring 1 5 81382 Ignitor Piezo Assembly 1 6 81381 Valve and Gas Assembly 1 7 893992 Control Knob 1 8 81377 Hose Regulator Assembly 10 1 1 2 5...

Page 12: ...No Service 01 Date Engineer Name Company Telephone No Unit Inspected Check Gas Lines For Wear Or Leaks Check Integrity Of Ori ce And Gas Ports Items Replaced License No Service 04 Date Engineer Name...

Page 13: ...stributors This product must be properly installed maintained and operated in accordance with the instructions provided herein Furthermore United States Stove Company requires reasonable proof of the...

Page 14: ...VOTRE REVENDEUR OU DIRECTEMENT AUPR S DU FABRICANT DE L APPAREIL L UTILISATION DE COMPOSANTS TIERS ANNULERA LA GARANTIE HF200C LISTE DES PIECES 1 2 5 6 3 4 8 7 Cl No De Pi ce Description Qt 1 893996 A...

Page 15: ...br leur 1 3 893994 Ensemble de c ne de br leur 1 4 893998 Anneau de chambre de combustion 1 5 893991 Bouton de controle 1 6 81380 Ensemble vanne et gaz 1 7 81376 Assemblage tuyau et r gulateur 10 pi...

Page 16: ...raccord POL fournis avec l appareil de chauffage IMPORTANT Faire correspondre la bande de couleur de l tiquette fix e au tuyau la couleur de l tiquette situ e pr s du raccord d entr e de gaz propane N...

Page 17: ...clics d allumage pi zo Continuez faire tourner et activer l allumeur jusqu ce que le br leur se allume 5 Une fois que le br leur se allume maintenez le bouton dans sur la position basse pendant 30 se...

Page 18: ...il des raccords du tuyau et autres l ments Si vous d celez la moindre odeur de gaz COMMUNIQUEZ IMM DIATEMENT AVEC VOTRE FOURNISSEUR EN GAZ COMBUSTIBLE N ATTENDEZ PAS ATTENTION N ALLUMEZ PAS L APPAREIL...

Page 19: ...pane loignez vous des endroits plus bas Utilisez le t l phone d un voisin et communiquez avec votre fournisseur en gaz combustible et votre service d incendies Ne retournez pas dans l immeuble ou dans...

Page 20: ...AU MONOXYDE DE CARBONE SONT LES MAUX DE T TE LES TOURDISSEMENTS ET LA DIFFICULT RESPIRATOIRE AVERTISSEMENT DANGER POUR LA QUALIT DE L AIR L UTILISATION D APPAREILS DE CHAUFFAGE CHAUFFAGE DIRECT DANS L...

Page 21: ...sive ou de coupure remplacez le tuyau par l ensemble de tuyaux recommand avant d utiliser l appareil de chauffage 9 Pour utilisation int rieure seulement La ventilation doit tre ad quate voir galement...

Page 22: ...la pr sence de fuite aux nouvelles connexions et raccords en utilisant un m lange d eau et de savon et suivez les instructions mentionn es Obtenez galement les conseils de votre d taillant quant votr...

Page 23: ...ON ET D INHALATION CONSERVEZ LES MAT RIAUX COMBUSTIBLES TELS QUE LES MAT RIAUX DE CONSTRUCTION LE PAPIER ET LE CARTON UNE DISTANCE S CURITAIRE DE L APPAREIL DE CHAUFFAGE COMME LE RECOMMANDENT LES INST...

Page 24: ...etien doit tre effectu par un fournisseur de services d entretien qualifi AVERTISSEMENT Le non respect des instructions telles qu indiqu es dans le pr sent guide risque d entra ner une explosion ou un...

Reviews: