background image

20

© 2021 United States Stove Company

Display is Flashing “E3”
Possible Causes

Possible Remedies: (Unplug stove first when possible)

The hopper is out of pellets

Refill the hopper.

The air dampener is too far open for a low feed 

setting

If on the low setting, you may need to close the dampener all the 

way.

The burnpot holes are blocked.

Remove the burnpot and thoroughly clean it.

The air inlet, the interior chambers, or exhaust 

system has a partial blockage.

Follow all cleaning procedures in the maintenance section of the 

owner's manual

The hopper safety switch has failed or hopper is 

open.

When operating the unit, be sure the hopper lid is closed so that 

the hopper safety switch will activate. Check the wires leading 

from the hopper safety switch to the control panel and auger 

motor for secure connections. Use a continuity tester to test the 

hopper safety switch; replace if necessary.

The auger shaft is jammed.

"Start by emptying the hopper. Then remove the auger motor by 

removing the auger pin, then remove the two bolts that hold the 

auger bracket to the auger tube. The auger bracket will now be 

able to be removed form the auger tube. Remove the two bolts 

on the side of the auger tube to remove the lower bearing of the 

auger. Pull the auger out of the tube to free the jam.

The auger motor has failed.

Remove the auger motor from the auger shaft and try to run the 

unit. If the motor will turn the shaft is jammed on something. If 

the motor will not turn, the motor is bad.

The Proof of Fire (POF) thermodisc has 

malfunctioned.

Temporarily bypass the POF thermodisc by disconnecting the 

two wires and connecting them with a short piece of wire. Then 

plug the stove back up. If the stove comes on and works, you need 

to replace the POF thermodisc. This is for testing only. DO NOT 

LEAVE THE THERMODISC BYPASSED. Your blowers will never 

shut off and if the fire went out the auger will continue to feed 

pellets until the hopper is empty if you leave the POF thermodisc 

bypassed.

The control board is not sending power to the POF 

thermodisc or other auger system components.

There should be a 5-volt (approximately) current going to the 

POF thermodisc after the stove has been on for 10 minutes.

TROUBLESHOOTING GUIDE

Summary of Contents for 5710-XH

Page 1: ...r fire officials about permits restrictions and installation requirements in your area NEVER OPERATE THIS PRODUCT WHILE UNATTENDED CAUTION Please read this entire manual before you install or use your...

Page 2: ...O OPERATE THIS WOOD HEATER IN A MANNER INCONSISTENT WITH THE OPERATING INSTRUCTIONS IN THE OWNER S MANUAL Heating Specifications Fuel Burn Rate lowest setting 1 5 lbs hr 0 7 kg hr Pellet size may effe...

Page 3: ...and_____________________________________________ If no Date of inspection of existing venting system ________________________________________________________________ COMMISSIONING Confirm Hearth Pad I...

Page 4: ...ed wires out of the top of the stove There will be two wire harnesses as shown 2 Unpack the top mount controls and ensure that the wiring harness shown is attached securely 3 Connect the factory insta...

Page 5: ...IS REQUIRED THIS UNIT MUST BE PLUGGED INTO A 110 120V 60 HZ GROUNDED ELECTRICAL OUTLET DO NOT USE AN ADAPTER PLUG OR SEVER THE GROUNDING PLUG DO NOT ROUTE THE ELECTRICAL CORD UNDERNEATH IN FRONT OF O...

Page 6: ...standards Needs to extend 18 to the front 8 beyond each side of the unit A Back to Stove U S A 1 26mm CAN 8 204 mm B Side to Stove U S A 6 153 mm CAN 8 204 mm C Front to Stove U S A 6 153 mm CAN 8 204...

Page 7: ...r star washer to penetrate paint or protective coating to ensure grounding Vent must be 3 or 4 inch PL Vent and must extend a minimum or 36 914 mm above the roof line of the mobile home and must be in...

Page 8: ...t pipe is not furnished with the unit and must be purchased separately PELLET VENT INSTALLATION The installation must include a clean out tee to enable collection of fly ash and to permit periodic cle...

Page 9: ...e every 4ft 1 22m to make the system more stable If you live in an area that has heavy snowfall it is recommended that the installation be taller than 3ft 0 91m to get above the snowdrift line This sa...

Page 10: ...he two digit display indicate the mode of operation Manual or T Stat The stove has to be in normal operation to be switched from Manual to T Stat mode Manual mode operates according to the 5 set level...

Page 11: ...FUEL INSTITUTE PFI Your pellet stove is designed to burn premium hardwood pellets that comply with the Pellet Fuels Institute PFI standard minimum of 40 lbs density per cubic ft 1 4 to 5 16 diameter...

Page 12: ...ing this period because the paint could be affected Attempts to achieve heat output rates that exceed heater design specifications can result in permanent damage to the heater AUTOMATIC IGNITOR 1 Fill...

Page 13: ...rature thermodisc This unit has a manual reset thermodisc This safety switch has two functions A To recognize an overheat situation in the stove and shut down the fuel feed or auger system B In case o...

Page 14: ...heat exchanger To access these clean outs you must remove both side panels The clean outs are secured to the firebox with 2 5 16 screws Remove the clean outs and vacuum out any accumulated ash This s...

Page 15: ...aned and if necessary repaired To clean the chimney disconnect the vent from the stove FLY ASH This accumulates in the horizontal portion of an exhaust run Though non combustible it may impede the nor...

Page 16: ...attempt to operate the unit with broken glass Replacement glass may be purchased from your U S Stove dealer If glass is broken follow these removal procedures 1 Remove the four 4 screws and glass ret...

Page 17: ...stove com The information in this owner s manual is specific to your unit When ordering replacement parts the information in this manual will help to ensure the correct items are ordered Before contac...

Page 18: ...ide about 1 4 after your stove cools down Restart your stove If your display shows E1 again close the slide another 1 4 and restart The convection blower is overheating and tripping the internal tempe...

Page 19: ...Combustion blower failure With the stove on check to see if the combustion blower is running If it is not you will need to check for power going to the combustion blower It should be a full current If...

Page 20: ...move the two bolts that hold the auger bracket to the auger tube The auger bracket will now be able to be removed form the auger tube Remove the two bolts on the side of the auger tube to remove the l...

Page 21: ...rating the unit be sure the hopper lid is closed so that the hopper safety switch will activate Check the wires leading from the hopper safety switch to the control panel and auger motor for secure co...

Page 22: ...The Home Possible Causes Possible Remedies Unplug stove first when possible There is a leak in the vent pipe system Inspect all vent pipe connections Make sure they are sealed with RTV silicone that...

Page 23: ...ve caused a jam Loose wire or connector Check all wires and connectors that connector to the auger motor high limit switch and the Molex connector Bad control board If the fuse is good the wires and c...

Page 24: ...Burnpot holes are blocked Remove the burnpot and thoroughly clean it Blockage in air intake pipe Visually inspect the air intake pipe that leads into the burnpot for foreign material Combustion blowe...

Page 25: ...99 Housing PCBA Controller 1 7 80491 Microswitch 1 8 80709 Room Blower 1 9 88347 T Disc Room Air Gasket 2 10 80601 T Disc Room Air 1 11 80599 T Disc Exhaust 1 12 80602 Exhaust Blower 1 13 80488 Drive...

Page 26: ...26 2021 United States Stove Company 1 25A 250V FUSE 7 5A 250V FUSE CORRECT WRONG Ensure the wires are connected to the bottom two prongs of the hopper switch as shown WIRING DIAGRAM...

Page 27: ...2021 United States Stove Company 27 NOTES...

Page 28: ..._____ Engineer Name _____________________________________ License No _________________________________________ Company ___________________________________________ Telephone No ________________________...

Page 29: ..._____________________ Service de 07 Date ______________________ Nom de l ing nieur _________________________________ N de licence ______________________________________ Compagnie _____________________...

Page 30: ...nited States Stove Company 1 25A 250V Fusible 7 5A 250V Fusible CORRECT FAUX Assurez vous que les fils sont connect s aux deux broches inf rieures de l interrupteur de la tr mie comme illustr SCH MA D...

Page 31: ...commande IR 1 4 69762 Pot de feu 1 5 892668 Couvercles de nettoyage des cendres 2 6 892199 Bo tier contr leur PCBA 1 7 80491 Commutateur de couvercle 1 8 80709 Sou eur de pi ce 1 9 88347 T Disc joint...

Page 32: ...lot de granul s utilis s est peut tre de mauvaise qualit Si possible essayez une autre marque de granul s Essayez aussi une marque compos e d un autre type de bois r sineux plut t que feuillus Des boi...

Page 33: ...de l arbre de la tari re et essayez de le faire fonctionner Si le moteur tourne c est l arbre qui est coinc sur quelque chose Si le moteur ne tourne pas il est d fectueux Tari re bloqu e Commencez par...

Page 34: ...tableau de commande n envoie pas de courant l allumeur V rifiez la tension qui arrive l allumeur lors du d marrage Ce doit tre la tension nominale Si la tension est inf rieure la valeur nominale v ri...

Page 35: ...erm pour permettre l interrupteur de s curit de la tr mie de s activer V rifiez le branchement des fils qui partent de l interrupteur de s curit de la tr mie jusqu au tableau de commande et au moteur...

Page 36: ...Retirez ensuite le moteur de la tari re en retirant la goupille de la tari re puis retirez les deux boulons qui fixent le support de tari re au tube de tari re Vous pouvez maintenant retirer le suppo...

Page 37: ...Panne du ventilateur de combustion Lorsque le po le est en marche v rifiez si le ventilateur de combustion est en fonctionnement Sinon v rifiez l alimentation lectrique du ventilateur de combustion Ce...

Page 38: ...e po le Si votre cran affiche nouveau E1 fermez la glissi re de 1 4 et recommencez Le ventilateur de convection surchauffe et d clenche l arr t de temp rature interne Enlevez la poussi re des bobinage...

Page 39: ...propri taire sont sp cifiques votre appareil Lors de la commande de pi ces de rechange les informations contenues dans ce manuel vous aideront vous assurer que les bons articles sont command s Avant...

Page 40: ...N UTILISEZ PAS de nettoyants abrasifs N effectuez PAS le nettoyage lorsque la vitre est CHAUDE N essayez pas de faire fonctionner l appareil avec du verre bris Le verre de remplacement peut tre achet...

Page 41: ...son de chauffage Pour nettoyer la chemin e d connecter l vacuation du po le CENDRES VOLANTES Elles s accumulent dans la portion horizontale du conduit d vacuation Bien qu elles ne soient pas combustib...

Page 42: ...s du nettoyage ou si le po le ne semble pas tre br ler correctement Si un aspirateur est utilis pour nettoyer votre po le nous vous sugg rons d utiliser l aspirateur AV15E AshVac L AV15E AshVac est co...

Page 43: ...moin vert repasse au rouge lorsqu on appuie sur la touche POWER Le moteur de la tari re s arr te et les ventilateurs continuent de fonctionner jusqu ce que la temp rature de la chambre de combustion i...

Page 44: ...le d marrage C est variable en fonction de votre installation et de l altitude Une fois le feu bien d marr r glez le registre pour obtenir la flamme voulue en l ouvrant au fur et mesure que vous augm...

Page 45: ...ranul s de bois dur de qualit sup rieure conformes la norme PFI Pellet Fuels Institute densit minimale de 40 lb par pied cube diam tre de 1 4 5 16 moins de 8 200 BTU lb humidit inf rieure 8 en poids c...

Page 46: ...e fonctionnement du po le peut tre Manuel ou command par un Thermostat Des diodes distinctes gauche de l cran deux chiffres indiquent le mode de fonctionnement Manuel ou T stat Le po le doit tre en mo...

Page 47: ...tion de tuyau d au moins 3 pi 0 91 m doit tre ajout e avec un chapeau horizontal pour achever l installation Un support doit tre plac juste au dessous du chapeau de sortie ou raison d un support tous...

Page 48: ...e conduit d vacuation pour po le granul s est con u pour tre d mont aux fins de nettoyage et doit tre v rifi plusieurs fois au cours de la saison de chauffage Le conduit d vacuation pour po le granul...

Page 49: ...ou 101 mm et doit d passer d au moins 36 po 914 mm au dessus de la fa ti re de la maison mobile elle doit tre install e avec un pare feu de plafond et un chapeau anti pluie homologu s UL En cas de d p...

Page 50: ...our Cuisini re U S A 1 26 CAN 8 204 B C t po le U S A 6 153 CAN 8 204 C De l avant au po le U S A 6 153 CAN 8 204 D Retour Flue 2 51 D GAGEMENTS Votre po le granules a t test et r pertori pour une ins...

Page 51: ...ASSAGE ET NE LE COINCEZ PAS SOUS LES MEUBLES ATTENTION ATTENTION LA COMBUSTION DU COMBUSTIBLE G N RE DU MONOXYDE DE CARBONE QUI PEUT S AV RER DANGEREUX POUR LA SANT EN L ABSENCE D UNE VENTILATION APPR...

Page 52: ...bles comme illustr 2 D ballez les meilleurs contr les de montage et de veiller ce que le faisceau de c blage illustr est fix 3 Connecter les install s en usine faisceaux de c blage sur le panneau de c...

Page 53: ...n date d inspection du syst me de ventilation existant ___________________________________________________________________ MISE EN SERVICE Confirmer l installation du tapis de foyer conform ment aux i...

Page 54: ...el d crit l installation et le fonctionnement du po le bois USSC 5710 XH Cet appareil de chauffage respecte les limites d mission de bois de berceau de l Environmental Protection Agency des tats Unis...

Page 55: ...tion de ce radiateur Contactez les responsables locaux du b timent ou des pompiers pour conna tre les permis les restrictions et les exigences d installation dans votre r gion NE JAMAIS UTILISER CE PR...

Reviews: