Run 1.xlsm
Client: USSC
Job #: 22-753
Model: KP5522
Tracking #: 121
Run #: 1
Technician: SJB
Date:
Particulate Sampling Data
Elapsed
Time
(min)
Gas Meter
(ft
3
)
Sample
Rate (cfm)
Dilution
Tunnel dP
(in H
2
O)
Orifice
dH
(in H
2
O)
Meter
Temp (°F)
Meter
Vacuum
(in Hg)
Pro. Rate
(%)
Scale
Reading
Weight
Change
Dilution
Tunnel
Flue
Filter
Ambient
2/18/2022
BOX A TEST DATA - ASTM E2779 / ASTM E2515
Fuel Weight (lb)
Temperature Data (°F)
102
19.179
0.190
0.030
1.49
65
-1.36
102
11.4
-0.1
85
278
73
69.6
103
19.369
0.190
0.031
1.51
65.1
-1.41
100
11.3
-0.1
85
278
73
69.6
104
19.559
0.190
0.032
1.49
65.1
-1.4
98
11.3
-0.1
85
276
73
69.7
105
19.749
0.190
0.031
1.49
65.2
-1.62
100
11.2
-0.1
85
275
73
69.7
106
19.939
0.190
0.030
1.49
65.1
-1.38
101
11.2
-0.1
85
273
73
69.7
107
20.130
0.191
0.031
1.50
65.2
-1.55
100
11.1
-0.1
85
275
73
69.8
108
20.320
0.190
0.030
1.50
65.1
-1.62
101
11.0
-0.1
85
276
73
69.9
109
20.510
0.190
0.031
1.49
65
-1.57
100
11.0
-0.1
85
275
73
69.8
110
20.699
0.189
0.031
1.50
65
-1.48
99
10.9
-0.1
85
275
73
69.7
111
20.889
0.190
0.032
1.49
65
-1.48
98
10.8
-0.1
85
276
73
70
112
21.078
0.189
0.031
1.50
65
-1.38
99
10.8
-0.1
85
273
73
69.9
113
21.268
0.190
0.031
1.49
65
-1.37
100
10.7
-0.1
85
274
73
69.9
114
21.458
0.190
0.030
1.50
65
-1.58
102
10.7
-0.1
85
273
73
70.1
115
21.648
0.190
0.031
1.50
65.1
-1.58
100
10.6
-0.1
85
273
73
69.8
116
21.838
0.190
0.031
1.50
65
-1.37
100
10.6
-0.1
85
273
73
69.8
117
22.029
0.191
0.031
1.50
64.8
-1.58
100
10.5
0.0
85
271
73
69.9
118
22.219
0.190
0.032
1.50
64.7
-1.49
98
10.4
-0.1
85
271
73
69.9
119
22.408
0.189
0.031
1.50
64.5
-1.38
99
10.4
-0.1
85
269
73
69.9
120
22.598
0.190
0.032
1.50
64.7
-1.57
98
10.3
-0.1
85
269
73
69.9
121
22.787
0.189
0.032
1.50
64.7
-1.6
98
10.3
-0.1
85
269
73
69.9
122
22.977
0.190
0.031
1.49
64.7
-1.39
100
10.2
-0.1
85
269
73
69.8
123
23.167
0.190
0.032
1.50
64.8
-1.61
98
10.2
-0.1
85
267
73
70
124
23.356
0.189
0.031
1.49
65.1
-1.5
99
10.1
-0.1
85
268
73
69.8
125
23.546
0.190
0.032
1.49
65.1
-1.58
98
10.1
0.0
84
266
73
69.9
126
23.736
0.190
0.032
1.50
65.1
-1.59
98
10.0
-0.1
84
270
73
69.7
127
23.927
0.191
0.031
1.49
64.8
-1.37
100
9.9
-0.1
84
272
73
69.4
128
24.117
0.190
0.031
1.50
64.6
-1.41
100
9.8
-0.1
85
272
73
69.5
129
24.306
0.189
0.030
1.50
64.2
-1.48
101
9.8
-0.1
85
272
73
69.2
130
24.496
0.190
0.032
1.50
63.9
-1.37
98
9.7
-0.1
85
271
73
69.2
131
24.685
0.189
0.032
1.49
63.9
-1.45
98
9.7
-0.1
85
269
73
69.2
132
24.875
0.190
0.031
1.49
63.9
-1.44
100
9.6
-0.1
85
271
73
69.3
133
25.064
0.189
0.031
1.49
63.9
-1.52
100
9.6
-0.1
85
270
73
69.3
134
25.254
0.190
0.032
1.49
64
-1.47
98
9.5
-0.1
85
273
73
69.4
135
25.444
0.190
0.032
1.49
64.1
-1.57
98
9.4
0.0
85
272
73
69.5
PFS-TECO
Page 13 of 32
Summary of Contents for KP5522
Page 11: ...Project 22 753 Model KP5522 Page 10 Appliance Front Appliance Left...
Page 12: ...Project 22 753 Model KP5522 Page 11 Appliance Right Appliance Rear...
Page 14: ...Project 22 753 Model KP5522 Page 13 Pellet Fuel Analysis...
Page 17: ...Project 22 753 Model KP5522 Page 16 Sealed Unit...
Page 54: ......
Page 55: ......
Page 56: ......
Page 58: ...Project 22 751 Model Charnwood Skye E700 Page 16 Tunnel Schematic...
Page 102: ......
Page 103: ......
Page 104: ......
Page 129: ...2022 United States Stove Company 25 NOTES...
Page 177: ...2022 United States Stove Company 25 NOTES...
Page 272: ...24 2022 United States Stove Company NOTES...
Page 308: ......
Page 309: ......
Page 311: ......
Page 312: ......
Page 318: ......
Page 319: ......