Installation
CLEArANCES
Your King stove has been tested and listed for installation in residential, mobile home, and alcove applications in
accordance with the clearances given in FIGURES 3-5 and TABLE 1.
NOTE: Distance “C” on the left-hand side of your King stove may need to be greater than the minimum required
clearance for suitable access to the control panel.
FigurE 3
SIDEWALL CLEARANCES
PARALLEL INSTALLATION
FigurE 4
SIDEWALL CLEARANCES
CORNER INSTALLATION
FigurE 5
ALCOVE CLEARANCES
PARALLEL
A - Backwall to unit
2.00 / 50mm
B - Sidewall to flue
13.00 / 330mm
C - Sidewall to top edge of unit
8.00 / 203mm
CORNER
D - Adjacent wall to unit
8.00 / 203mm
ALCOVE
E - Alcove depth
36.00 - 914 mm
F - Alcove height
60.00 - 1520mm
TABLE 1
CLEARANCES