Safety Precautions

IMPORTANT:  Read this entire manual before installing 

and  operating  this  product.    Failure  to  do  so  may 

result in property damage, bodily injury, or even death.  

Proper installation of this stove is crucial for safe and 

efficient operation.
Install  vent  at  clearances  specified  by  the  vent 

manufacturer. 

Do not connect the pellet vent to a vent serving any 

other appliance or stove.
Do  not  install  a  flue  damper  in  the  exhaust  venting 

system of this unit.
Use of outside air is not required for this unit.   
Contact  your  local  building  officials  to  obtain  a 

permit and information on any additional installation 

restrictions or inspection requirements in your area.
Do  not  throw  this  manual  away.   This  manual  has 

important  operating  and  maintenance  instructions 

that you will need at a later time.  Always follow the 

instructions in this manual.
This 

appliance is designed

 

for the use of pelletized fuel

that meet or exceed the standard set by the Pellet Fuel

 

Institute (PFI). The use of other fules will void warranty.

Never  use  gasoline,  gasoline-type  lantern  fuel, 

kerosene,  charcoal  lighter  fluid,  or  similar  liquids  to 

start or ’freshen up’ a fire in this stove.  Keep all such 

liquids well away from the stove while it is in use.
A working smoke detector must be installed in the same 

room as this product.
Do not unplug the stove if you suspect a malfunction.  

Turn the ON/OFF SWITCH to ”OFF’ and contact your 

dealer.
Your stove requires periodic maintenance and cleaning 

(see ”MAINTENANCE ”). Failure to maintain your stove 

may lead to improper and/or unsafe operation.
Disconnect  the  power  cord  before  performing  any 

maintenance!  NOTE: Turning the ON/OFF Switch to 

”OFF” does not disconnect all power to the electrical 

components of the stove.
Never try to repair or replace any part of the stove un

-

less instructions for doing so are given in this manual.  

All other work should be done by a trained technician.
Do  not  operate  your  stove  with  the  viewing  door 

open.   The  auger  will  not  feed  pellets  under  these 

circumstances and a safety concern may arise from 

sparks or fumes entering the room.

 

 

 

 

 

 

Allow  the  stove  to  cool  before  performing  any 

maintenance or cleaning.  Ashes must be disposed 

in a metal container with a tight fitting lid.  The closed 

container  of  ashes  should  be  placed  on  a  non-

combustible surface or on the ground, well away from 

all combustible materials, pending final disposal.
The exhaust system should be checked monthly during 

the burning season for any build-up of soot or creosote. 
Do not touch the hot surfaces of the stove.  Educate all 

children on the dangers of a high-temperature stove. 

Young children should be supervised when they are 

in the same room as the stove.
The hopper and stove top will be hot during operation; 

therefore, you should always use some type of hand 

protection when refueling your stove.  
A power surge protector is required.  This unit must 

be  plugged  into  a  110  -  120V,  60  Hz  grounded 

electrical outlet. Do not use an adapter plug or sever 

the grounding plug. Do not route the electrical cord 

underneath,  in  front  of,  or  over  the  heater.    Do  not 

route the cord in foot traffic areas or pinch the cord 

under furniture.
The heater will not operate during a power outage. If a 

power outage does occur, check the heater for smoke 

spillage and open a window if any smoke spills into 

the room.
The  feed  door  must  be  closed  and  sealed  during 

operation.
Never  block  free  airflow  through  the  open  vents  of 

the unit.
Keep foreign objects out of the hopper.
The moving parts of this stove are propelled by high 

torque electric motors.  Keep all body parts away from 

the auger while the stove is plugged into an electrical 

outlet.  These moving parts may begin to move at any 

time while the stove is plugged in.
Do not place clothing or other flammable items on or 

near this stove. 
When  installed  in  a  mobile  home,  the  stove  must 

be grounded directly to the steel chassis and bolted 

to  the  floor.    WARNING—THIS  UNIT  MUST  NOT 

BE  INSTALLED  IN  THE  BEDROOM  (per  HUD 

requirements).    CAUTION—THE  STRUCTURAL 

INTEGRITY OF THE MOBILE HOME FLOOR, WALL, 

AND CEILING/ROOF MUST BE MAINTAINED

.  

This appliance is not intended for commercial use.

 

 

 

 

* This appliance is a freestanding heater.  It is not intended to be attached to any type of ducting.  It is not a furnace.

NorthlineExpress.com

http://www.northlineexpress.com

Toll-Free 1-866-667-8454

Summary of Contents for King

Page 1: ...injury or even death Contact your local building or fire officials about restrictions and installation inspection requirements in your area Save these instructions Owner s Manual UNITED STATES STOVE C...

Page 2: ...ecial Mobile Home Requirements 10 understanding your stove 11 control panel overview 12 Operation 13 15 Unit Preparation 13 Performing Initial Test 13 Performing a Dry Run 13 Start Up Procedure 14 Shu...

Page 3: ...r fumes entering the room Allow the stove to cool before performing any maintenance or cleaning Ashes must be disposed in a metal container with a tight fitting lid The closed container of ashes shoul...

Page 4: ...HZ 3 0 Amps Watts operational 175 approx Watts igniter running 425 approx Electrical Specifications FUEL CONSIDERATIONS Your Pellet stove is designed to burn premium hardwood pellets that comply with...

Page 5: ...nician install your King stove preferably an NFI certified specialist Installation IMPROPER INSTALLATION The manufacturer will not be held responsible for damage caused by the malfunc tion of a stove...

Page 6: ...mum required clearance for suitable access to the control panel FIGURE 3 SIDEWALL CLEARANCES PARALLEL INSTALLATION FIGURE 4 SIDEWALL CLEARANCES CORNER INSTALLATION FIGURE 5 ALCOVE CLEARANCES PARALLEL...

Page 7: ...12 feet or if the installation is over 2 500 feet above sea level We recommend the use of Simpson Dura Vent or Metal Fab pipe if you use other pipe consult your local building codes and or building in...

Page 8: ...n adjacent to public walkways E Minimum 2 foot clearance above any grass plants or other combustible materials F Minimum 3 foot clearance from an forced air intake of any appliance G Minimum 2 foot cl...

Page 9: ...by simply adding the clean out section and vertical pipe inside until ground level is reached With this installation you have to be aware of the snowdrift line dead grass and leaves We recommend a 3 f...

Page 10: ...your installation FIGURE 9 TYPICAL FRESH AIR TERMINATION FIGURE 8 EXHAUST INLET LOCATIONS Special Mobile Home Requirements WARNING Do not install in a sleeping room CAUTION The structural integrity o...

Page 11: ...y the exhaust or draft fan must be maintained precisely Too little air will result in a flame that is non energetic or lazy If the fuel continues to flow with too little air for long enough the burn p...

Page 12: ...eed will automatically be adjusted in accordance with the heat range setting By pressing the Room Fan up arrow you can adjust the fan speed setting up to Rf 9 The room fan must operate at a level grea...

Page 13: ...ugr The auger motor is turned on full If the Auger Fuse is not blown and the fuse detection circuit is functioning the Heat Range LED will be lit and the other three top row LEDs will be off Hopper Sw...

Page 14: ...is plugged into an outlet an outlet surge protector is highly recommended Fill the hopper with wood pellets do not allow any part of the bag or any other foreign material into the hopper as this may j...

Page 15: ...re set limit the temperature limit control will automatically slow down the auger feed rate until the temperature returns to a normal condition Even though the heater will operate on the highest setti...

Page 16: ...rt up Painted Surfaces Painted surfaces may be wiped down with a damp cloth If scratches appear or you wish to renew your paint contact your Authorized King Dealer to obtain a can of suitable high tem...

Page 17: ...the exhaust system clean as needed Check that the pressure switch connection to the firebox is free of ash or clear of obstructions Auger system is jammed or there is a bridging of the fuel in the hop...

Page 18: ...on or for a 15 minute period after the stove was turned off or for the stove to cool down or for the door to be closed Flashing dash in Heat Range Display This indicates that the stove is in the norma...

Page 19: ...USSC 19 Parts Diagram 11 3 2 1 5 6 4 7 9 8 10 12 Viewing Door Detail NorthlineExpress com http www northlineexpress com Toll Free 1 866 667 8454...

Page 20: ...29 31 1 31 891190 Bottom Bushing Plate 1 32 891180 Auger Cover 1 33 891161 Weld Bot Plate Retainer 1 34 891195 Bracket Drive Motor 1 35 891169 Hose Heater 3 in 36 80488 Drive Motor 1 37 83529 Hairpin...

Page 21: ...USSC 21 Wiring Diagram GRAY BLACK NorthlineExpress com http www northlineexpress com Toll Free 1 866 667 8454...

Page 22: ...22 USSC Notes NorthlineExpress com http www northlineexpress com Toll Free 1 866 667 8454...

Page 23: ...USSC 23 Notes NorthlineExpress com http www northlineexpress com Toll Free 1 866 667 8454...

Page 24: ...ached to the heater When ordering repair parts always give the following infor mation as shown in this list 1 The part number 2 The part description 3 The model number 5510 4 The serial number _______...

Reviews: