background image

Warranty

28

United Spa Controls One Year Limited Warranty  

United Spa Controls warrants, to the original purchaser, the spa control equipment against defects in 

materials or workmanship for a period of fourteen months from date of manufacture. The obligation 

of this warranty shall be limited to repairing or replacing the part, which in the opinion of the company 

shall be proved defective in materials or workmanship. This limited warranty does not include the 

limitations described below.

Limitations  of  Coverage:

  This warranty does not cover failures due to: damage, freezing, power 

failure, power reduction, unusual atmospheric conditions, rust or corrosion, repairs necessary because 

of operator negligence, improper re-packaging, and damage incurred in shipping. This warranty does 

not cover thermostat calibration, plumbing, and expendable items (gaskets, o-rings, filter cartridges).

Acts  Invalidating  Warranty: 

This warranty shall be invalid if this equipment has been subjected 

to alterations, misuse or abuse, improper water chemistry, improper handling, improper installation, 

repairs (or attempted repairs) which in United Spa Controls’ judgment adversely affects the product’s 

performance/reliability, or if the equipment is used for commercial purposes (used for other than single 

family household purposes). Misuse and abuse shall  include application, installation, or operation 

outside  of  the  environment  and  limitations  for  which  it  was  designed. This  warranty  shall  also  be 

invalid if the spa equipment is damaged by earth or ground fill movement, fire, flood, wind, lightning, 

by act of God, accident, or by intentional, reckless, or negligent acts of any person.

Warranty Performance: 

All warranty service and/or replacement of parts must be performed by an 

individual or service company that has been authorized by United Spa Controls. If within the warranty 

period, any such products shall prove defective, it shall be replaced at United Spa Controls’ option as 

follows: 1) The original retail purchaser shall first contact the point of purchase or the installing dealer, 

as soon as possible after discovery of the defect, but in no event later than the expiration date of this 

warranty. Processing claims should be initiated by the point of purchase or the installing dealer. 2) 

A Return Merchandise Authorization (RMA) form must be completed and submitted to United Spa 

Controls by the point of purchase or the installing dealer. 3) United Spa Controls will issue an RMA for 

eligible items that are not out of their warranty period. 4) Defective items may then be packaged along 

with note that contains the issued RMA number and return shipping information in a box marked with 

the issued RMA number and shipped to: United Spa Controls, 5614 E La Palma Ave, Anaheim, CA 

9287. The customer must pay for all shipping charges and no product shall be returned to United Spa 

Controls without prior consent. 5) After receipt of the products, supporting documents, and verification 

of the nature and cause of the defect, United Spa Controls will replace or repair the defective product 

or issue warranty credit for eligible items at United Spa Controls’ option.

Removal  charges,  re-installation  charges,  any  other  associated  labor,  and  freight  charges  to  and 

from  United  Spa  Controls  of  the  failed  part  shall  be  the  purchaser’s  responsibility. Any  warranty 

replacement or repair shall be subject to the terms and condition of this warranty for the remainder 

of the original period of coverage. United Spa Controls reserves the right to inspect any malfunction 

or defect on location.

Disclaimers, Legal Remedies:

 This warranty is limited and shall be in lieu of all other warranties, 

expressed or implied, including but not limited to, any implied warranty or merchantability or fitness 

for a particular purpose. There are no other warranties that extend beyond the description of the face 

hereof. In no event shall United Spa Controls be liable for labor or material charges in connection with 

removal or replacement of the defective products. United Spa Controls is not liable for the incidental 

or consequential damages, loss of profit, loss of time, inconvenience and incidental expenses. Some 

states do not allow the exclusion or limitation of incidental or consequential damages, so the above 

limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you 

may also have other rights, which vary state to state. United Spa Controls reserve the right to change 

its warranty at any time.

Summary of Contents for T8-X Topside

Page 1: ...T8 S T8 X Topside Installation Manual User s Guide For C5 Series Spa Controls with the T8 S T8 X Topside Revision 09 13...

Page 2: ...opside s programming as mis programming can result in malfunction or possible damage Please contact your dealer or a locally licensed service center for service and technical support Warranty Disclaim...

Page 3: ...s 2 Disclaimers 1 Safety 4 For Qualified Service Professionals Only T8 Topside Installation 7 About The T8 Topside 8 Using The T8 Topside 9 For Qualified Service Professionals Only T8 Topside Initial...

Page 4: ...s 17 Interface Settings 18 Lock Operation 19 Heating Modes Standard and Economy 18 Operation Instructions 20 Temperature Operation 20 Heating Modes Standard and Economy 21 Toggling Display Orientation...

Page 5: ...VERTISSEMENT POUR VITER QUE LES CHEVEUX OU UNE PARTIE DU CORPS PUISSENT TRE ASPIR S NE PAS UTILISER UNE CUVE DE RELAXATION SI LES GRILLES DE PRISE D ASPIRATION NE SONT PAS TOUTES EN PLACE 3 Warning Pe...

Page 6: ...ssibly pregnant women should consult a physician before using a spa or hot tub AVERTISSEMENT LES FEMMES ENCEINTES QUE LEUR GROSSESSE SOIT CONFIRM E OU NON DEVRAIENT CONSULTER UN M DECIN AVANT D UTILIS...

Page 7: ...uction ATTENTION LA TENEUR DE L EAU EN MATI RES DISSOUTES DOIT TRE CONFORME AUX DIRECTIVES DU FABRICANT 14 Hyperthermia occurs when the internal temperature of the body reaches a level several degrees...

Page 8: ...e topside cable through the cutout in the spa s shell and down to the control box Then plug the opposite end of the topside cable into the topside receptacle on the control box Simply affix the topsid...

Page 9: ...throughout this user s guide The difference between the T8 S and the T8 X is that the T8 X has an Jets 3 button to operate a 3rd booster pump or air blower T8 X Only There is no Jets 3 Button on T8 S...

Page 10: ...it will briefly flash between T8 S or T8 X and the current software version by showing a V followed by a number Example V 03 while it starts up All configurable settings are saved to permanent memory...

Page 11: ...on menu consisting of five codes that configure what components the system will operate and what maximum amperage the system will operate at Each code has a number of options that the code can be set...

Page 12: ...30A 240V Operation No heat with anything other then P 1 Lo Speed Code 5 Heater Operation Option 1 Electric Heater operates with Lo Speed Pump 1 Option 2 Electric Heater operates with Circulation Pump...

Page 13: ...e out delay so taking longer then 10 seconds between steps will cause the topside to time out and resume normal operation Step 1 Press and the display will read Step 2 Press Hold for 15 seconds until...

Page 14: ...t to an option that conflicts with the missing option So if you program the topside to use the Jets 2 button to operate a two speed Pump 2 you will no longer see the code option allowing an air blower...

Page 15: ...g between and making changes to these settings which will be referenced throughout this section Entering the User Settings Menu Step 1 Press and the display will read Step 2 Press again to see the fir...

Page 16: ...view change thru thru The will actually show the currently set hour Filter Cycle Duration Press to view change thru thru Filter Cycle 1 Start Time Press to view change thru Filter Cycle 2 Start Time...

Page 17: ...ce Temperature Scale Press to view change or Fahrenheit Celsius Time Display Press to view change or Buzzer Beep on Keypress Press to view change or Temp Settings Lock Press to view change or Lock Set...

Page 18: ...installed If set to zero there will be no filtration cycles while setting between 1 12 will set the duration of each filtration cycle accordingly The factory default filter cycle duration is 2 hours...

Page 19: ...changed by pressing Temp Up Time Display By factory default Time Display is set to ON This means that during normal operation the display will flash between the current time and the current temperatur...

Page 20: ...ngs menu pressing the Menu button will display LOCK instead of MENU This prevents accessing the user settings menu changing the heat mode standard or economy explained later in this section and access...

Page 21: ...economy mode displays the currently set temperature for approximately 4 seconds While the currently set temperature is being displayed Press to increase the set temperature You can press and release...

Page 22: ...ump 1 is manually activated if there is no 24hr Circulation Pump and during filtration cycles In Economy mode if the current temperature falls below the set heat temperature the Heat indicator light w...

Page 23: ...o make the display readable from either inside or outside of the hot tub Screen orientation can be toggled at any time from the standard operating display when the display is showing the current tempe...

Page 24: ...on Dual or Triple Pump Systems Press to toggle between Lo Speed Hi Speed Off When Hi Speed of Pump 1 is running the Jets 1 indicator light will be lit When Lo Speed of Pump 1 is running the Jets 1 ind...

Page 25: ...Pump 2 or dual speed Pump 2 Single Speed Pump 2 Operation Press to toggle between On Off Dual Speed Pump 2 Operation Press to toggle between Lo Speed Hi Speed Off When Hi Speed of Pump 2 is running th...

Page 26: ...er 30 minutes of operation Operating the Spa Light To operate the spa light simply press to toggle between On Off The light will automatically shut off after 4 hours of operation Note If your spa also...

Page 27: ...briefly when Lo Speed of Pump 2 is activated Hi Speed Pump 3 This message will display briefly when Hi Speed of Pump 3 is activated T8 X Only Air This message will display briefly when the air blower...

Page 28: ...or Error The temperature sensor is malfunctioning or not properly connected Reconnect or replace temperature sensor as needed Hi Limit Sensor Error The hi limit sensor is malfunctioning or not properl...

Page 29: ...iration date of this warranty Processing claims should be initiated by the point of purchase or the installing dealer 2 A Return Merchandise Authorization RMA form must be completed and submitted to U...

Page 30: ...United Spa Controls 5614 E La Palma Ave Anaheim CA 92807 Web UnitedSpaControls com E mail support unitedspacontrols com Phone 714 982 0170 Fax 888 715 0286 2019 United Spa Controls All rights reserved...

Reviews: